SSANGYONG Korando 2012 Manual page 485

Hide thumbs Also See for Korando 2012:
Table of Contents

Advertisement

15-20
(4) Cooling Fan and A/C Compressor Control
Conditions for cooling fan
The cooling fan module controls the cooling fan relay, high speed relay and low speed relay.
The cooling fan is controlled by the series and parallel circuits
A/C
Cooling
switch
fan
OFF
OFF
LO
HI
LO
HI
ON
HI
HI
A/C compressor OFF conditions
Output voltage according to refrigerant pressure
The output voltage from refrigerant pressure sensor is 1.7 V to 3.5 V when the refrigerant pressure is 10
to 24 kgf/㎠ with A/C "ON".
Cooling fan control by ATF temperature
ATF temperature
Over 110˚C
Coolant temperature
Coolant temp.<90℃
90℃≤Coolant temp.<105℃
105℃≤Coolant temp.
Coolant temp.<105℃
105℃≤Coolant temp.<115℃
115℃≤Coolant temp.
-
Coolant temperature: over 118℃
-
Approx. 4 seconds after starting the engine
-
When abrupt acceleration
-
Refrigerant pressure:
* OFF below 2.0 kg/㎠, then ON over 2.4 kg/㎠
* OFF over 32 kg/㎠, then ON below 26.0 kg/㎠
Cooling fan speed
Refrigerant
pressure
-
-
-
Refrigerant
pressure<18 bar
18 bar≤Refrigerant
pressure
-
-
HI
A/C
compressor
ON
OFF (cut)
Remark
-

Advertisement

Table of Contents
loading

Table of Contents