• Power failures (max. 10 entries)
• Card failures (max. 150 entries)
If the maximum number of entries is exceeded, the oldest entry in each case is de-
leted.
These 4 Event Logs protocols are not printed out automatically; likewise, your at-
tention is not drawn to any incoming event message. The protocols have to be re-
trieved manually in the Fault & Maintenance Manager or printed out.
See also:
Event messages entered in the protocols of the Event Logs can also be
retrieved on the Office 45 using the System Assistant function on
Office 45 (see
E-mail signal destination
With the e-mail client integrated in the communication server, event messages can
be sent to internal or external e-mail destinations. After a first-start of the commu-
nication server, the signal destination
event table 5. Up to 5 e-mail destinations can be defined in the Fault & Mainte-
nance Manager, and e-mail notification can be activated or deactivated globally.
For the communication server to send the e-mails, the IP address or the host name,
the port and, where necessary, a user name with password must be configured un-
der
SMTP server
in the Configuration Manager.
Testing the signal destination configuration
To test the configuration, you can trigger a test event message via the Fault & Main-
tenance Manager. The event message is signalled without any delay, directly at the
selected signal destination.
If the communication server is connected with AMS via a TA, the test event mes-
sages will be signalled only once the connection is cleared down.
Aastra 470 as of R1.2
syd-0337/1.2 – R1.2 – 11.2011
"Maintenance menu on the Office 45", page
E-mail destination
Operation and Maintenance
224).
is automatically allocated
215