9. Pull out the spring clips at the water connection (Figure 5-28).
10. Remove the mounting platform, shelf screws of the flow-thru heater
(Figure 5-28, Item. 1).
11. Remove the flow-thru heater.
1 Temperature limiter
2 Temperature fuse
3 Temperature sensor
Figure 5-29: CVA4070 Flow-thru Heater Temperature
12. Remove the temperature sensor, temperature limiter and temperature
fuse from the flow-thru heater (Figure 5-29, Items 1 – 3).
13. Pull the connectors off the flow-thru heater.
Warning!
To prevent malfunctions in the water system (for example clogging of the
valves), never use grease, oil or other lubricants when assembling the
water supplying components.