Brew unit blocked.
Disconnect the appliance from the main power supply.
Remove any foreign matter.
Clean the affected components
Defective microswitch or no continuity in connectors.
Check the connecting cables.
Replace the connecting cables as necessary.
Position control microswitch– Check
Replace the microswitch if necessary.
Brew unit drive defective.
Note
When installing the brew unit, make sure that the pawl is set to the home
position, refer to Figure 6-1. Brew unit drive, home position.
Install a new brew unit drive.
6.3.13

F80 Cause

Flow-thru heater coffee/hot water (2R1) does not heat.
Flow-thru heater coffee/hot water – Check
If necessary, Flow-thru heater coffee/hot water – Remove
Install a new flow-thru heater coffee/hot water.
Temperature fuse has tripped.
Replace the temperature fuse.
6.3.14

F81

Flow-thru heater steam does not heat.
Flow-thru heater steam – Check
If necessary, Flow-thru heater steam – Remove
Install a new flow-thru heater steam.
Temperature fuse has cut out.