6.3.3
F1
Short circuit in the temperature sensor NTC coffee/hot water
Check the connecting cables.
Replace the connecting cables if necessary.
Temperature sensor Flow-thru heater coffee/hot water– Check,
0214.46.
Check the temperature sensor.
6.3.4
F2
Open circuit temperature sensor NTC coffee/hot water
Check the connecting cables.
Replace the connecting cables if necessary.
Temperature sensor Flow-thru heater coffee/hot water– Check,
0214.46.
Replace the temperature sensor if necessary.
6.3.5
F3
Short circuit temperature sensor NTC steam
Check the connecting cables.
Replace the connecting cables if necessary.
Temperature sensor Flow-thru heater steam.
Replace the temperature sensor if necessary.
6.3.6
F4
Open circuit temperature sensor NTC steam
Check the connecting cables.
Replace the connecting cables if necessary.
Temperature sensor Flow-thru heater steam
Replace the temperature sensor if necessary.