Technical Information
6.1.13
Water Hardness – Set
Initial requirements
1. Switch the appliance off.
Accessing
Note
Complete the access within 10 seconds.
1. Touch pad Clear and hold.
2. Touch pad On/Off once.
3. Release pad Clear.
4. Touch pad Clear 5 times and at the 5th time, hold it until the
programming mode appears.
Acknowledgement indicator
The display shows the positions of the programming mode
Programming.
Options
1. Touch pad next to Water hardness.
2. Touch pad next to the desired setting.
3. Back (without saving): Touch pad Clear.
Water Hardness Settings
Table 6-7: CVA4070 Water Hardness Settings
Save and quit
1. Save and back: Touch pad next to OK.
2. End: Touch pad On/Off.
Quit (without saving)
1. Touch pad On/Off.
Soft
Medium
Hard
Very Hard
110
CVA4070 / CVA4075 Coffee Systems
Value (approx.) until message "50
servings until descale"
gr/gal
Flow coffee/hot water
(pulses)
0 - 4
150.000
5 - 9
144.000
10 - 18
108.000
> 18
72.000
Discharge
steam (min)
120
90
60
30