Figure 5-41: Cva4070 Pump Retaining Screws Removal - Miele CVA 4075 Technical Information

Coffee systems
Table of Contents

Advertisement

Technical Information
1 Pump retaining screws
2 Temperature limiter

Figure 5-41: CVA4070 Pump Retaining Screws Removal

9. Pull the connectors off the pump.
10. Remove the pump bracket retaining screws (Figure 5-41, Item 1).
11. Remove the pump.
12. Remove the retaining clip from the 90 ° connector and disconnect the
teflon hose (Figure 5-41).
13. Pull the silicone hose off the pump (Figure 5-41).
14. Unclip the temperature limiter and remove it (Figure 5-41, Item 2).
15. Take the retaining brackets off the pump.
Warning!
To prevent malfunctions in the water system (for example clogging of the
valves), never use grease, oil or other lubricants when assembling the
water supplying components.