13.1 Digital Operator Monitor Display

The following table shows the contents of the Digital Operator monitor display.
LED
Name
Fref
Frequency reference
Fout
Output frequency
Iout
Output current
kWout
Output voltage
FWD/REV RUN
F/R
command
Montr
Monitor
Firmware – S2011 and S3012
Revision: 1 (9/98)
Table 28
Digital Operator Monitor Display
Frequency reference can be monitored/set.
Setting/display unit depends on display mode (n024).
Output frequency can be monitored.
Display unit depends on display mode (n024).
Output current can be monitored in units of 0.1 A (1 A for 1000 A and above).
Output voltage can be monitored in units of 0.1 kW (1 kW for 1000 k and above).
FWD/REV RUN command can be set/monitored.
Setting enabled during RUN command from Digital Operator.
FWD run displays For, REV run displays rev.
The following contents can be monitored.
No.
Frequency reference (same as Fref)
U−01
Output frequency (same as Fout)
U−02
U−03
Output current (same as Iout)
U−04
Output voltage reference can be monitored in units of 1 V
DC voltage can be monitored in units of 1 V
U−05
Output power (same as kWout)
U−06
Input terminal status can be monitored (Terminals S1 to S6)
U−07
Inverter status can be monitored
U−08