Selecting Stopping Method

6.4.1.

Selecting Stopping Method (n004)

Selects the stopping method suitable for the application.
Setting
0
1
2
3
§
Deceleration to Stop (n004 = 0)
Upon removal of the FWD or REV RUN command, the motor decelerates at the deceleration rate determined by the
time set to decel time 1 (n020), and DC Injection Braking is applied immediately before stop. If the decel time is
short or the load inertia is large, an overvoltage (OV) fault may occur at deceleration. In this case, increase the decel
time or install an optional Braking Resistor (can be equipped with GP5).
Braking torque
§
Coast to Stop (n004 = 1)
Upon removal of the FWD or REV RUN command, the motor starts coasting.
Firmware – S2011 and S3012
Revision: 1 (9/98)
Description
Deceleration to stop (Factory setting)
Coast to stop
Coast to stop with timer 1
Coast to stop with timer 2
Figure 36 Stopping Method
(Deceleration to Stop)
:
Without Braking Resistor
With Braking Resistor
Figure 37 Stopping Method
(Coast to Stop)
48
:
Approximately 20% torque of motor rating
:
Approximately 150% torque of motor rating