6.3.7

Automatic Restart after Momentary Power Loss (n051)

When momentary power loss occurs, operation restarts automatically.
Setting
0
[
1
=
2
Hold the Operation command to continue operation after recovery from a momentary power loss.
=
When 2 is selected, operation restarts if power supply voltage reaches its normal level. No fault signal is output.
6.3.8.

Soft-Start Characteristics (n023)

To prevent shock during machine starting and/or stopping, accel/decel can be performed in S-curve pattern.
Note: S-curve characteristic time is the time from accel/decel rate 0 to a regular accel/decel rate determined by the set
accel/decel time.
The following time chart shows switching from FWD/REV at deceleration to stop.
Firmware – S2011 and S3012
Revision: 1 (9/98)
Continuous operation after power recovery within 2 seconds
Continuous operation after power recovery within control logic time
(No fault output. Restarts only while control power supply is ON.)
Setting
S-curve Characteristic Time
0
S-curve not provided
1
0.2 s (Factory setting)
2
3
Figure 26 S-Curve Characteristic Timing
Figure 27 S-Curve Characteristic FWD/REV Operation
Description
Not provided (Factory setting)
0.5 s
1.0 s
42
© Saftronics, Inc.