12.1 Constant List - Saftronics FP5/GP5 Series Technical Manual

Table of Contents

Advertisement

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor
Chapter 12: Constant List

12.1 Constant List

Constant
Function Name
n001
Password
n002
Operation mode selection
n003
Input voltage
n004
Stopping method selection
n005
Power rotation
n006
Reverse run prohibit
n007
LOCAL/REMOTE key function
n008
Stop key function
Frequency reference setting method
n009
from Digital Operator
V/f pattern selection (same as V/f
n010
LED)
Motor rated voltage
n011
(same as Vmtr LED)
n012
Maximum output frequency
n013
Maximum voltage
n014
Maximum voltage output frequency
n015
Middle output frequency
n016
Middle frequency voltage
n017
Minimum output frequency
n018
Minimum output frequency voltage
Acceleration time 1
n019
(same as Accel LED)
Deceleration time 1
n020
(same as Decel LED)
n021
Acceleration time 2
Firmware – S2011 and S3012
Revision: 1 (9/98)
Table 27
Constant List
Description
0
: n001 read and set, n002 to n108 read only
1
: n001 to n034 read and set, n035 to n108 read only
2
: n001 to n049 read and set, n050 to n108 read only
3
: n001 to n108 read and set
4
: Not used
5
: Not used
: 2-wire initialization − reset (Japanese standard)
6
: 3-wire initialization − reset (Japanese standard)
7
: 2-wire initialization − reset (U.S. specifications)
8
: 3-wire initialization − reset (U.S. specifications)
9
10 : 2-wire initialization – reset (European specifications)
11 : 3-wire initialization – reset (European specifications)
(Setting)
(Operation)
0
:
Operator
1
:
Terminal
2
:
Operator
3
:
Terminal
4
:
Operator
5
:
Terminal
6
:
Serial com
7
:
Serial com
8
:
Serial com
Unit
:
0.1V
Setting range :
150.0 to 255.0V (510V for 400V units)
0
: Deceleration to stop
1
: Coast to stop
2
: Coast to stop with timer 1
3
: Coast to stop with timer 2
0
: CCW
1
: CW
0
: Reverse run enabled
1
: Reverse run disabled
0
: Disabled
1
: Enabled
0
: STOP key is effective when operated from Digital Operator
1
: STOP key is always effective
0
: ENTER key not used
1
: ENTER key used
0 to E
:
15 preset V/f patterns
F
:
Custom V/f pattern with voltage limit
FF
:
Custom V/f pattern without voltage limit
Unit
:
0.1V
Setting range :
150.0 to 255.0V (510 V for 400V units)
Unit
:
0.1Hz
Setting range :
50.0 to 400.0Hz
Unit
:
0.1V
Setting range :
0.1 to 255.0V (510 V for 400V units)
Unit
:
0.1HZ
Setting range :
0.2 to 400.0V
Unit
:
0.1Hz
Setting range :
0.1 to 399.9Hz
Unit
:
0.1V
Setting range :
0.1 to 255.0V (510V for 400V units)
Unit
:
0.1Hz
Setting range :
0.1 to 10.0Hz
Unit
:
0.1V
Setting range
0.1 to 50.0V
Unit
:
0.1 seconds (1 seconds for 1000 seconds and above)
Setting range :
0.0 to 3600 seconds
Unit
:
0.1 sec (1 seconds for 1000 seconds and above)
Setting range :
0.0 to 3600 seconds
Unit
:
0.1 seconds (1 seconds for 1000 seconds and above)
Setting range :
0.0 to 3600 seconds
84
(Reference)
Operator
Operator
Terminal
Terminal
Serial com
Serial com
Serial com
Operator
Terminal
Factory
Setting
1
3
200.0V
(400.0V)
0
0
0
1
1
1
1
200.0V
60.0 Hz
200.0V
60.0Hz
3.0Hz
15.0V
1.5Hz
10.0V
10.0
seconds
10.0
seconds
10.0
seconds