Chapter 4: Operation
4.4.2

Operation Check Points

Check the following items during operation.
o
Motor rotates smoothly.
o
Motor rotates in the correct direction.
o
Motor does not have abnormal vibration or noise.
o
Acceleration and deceleration are smooth.
o
Current matches the load flow.
o
Status indicator LED's and Digital Operator display are correct.
4.4.3

Example of Basic Operation.

§
Operation by Digital Operator
The diagram below shows a typical operation pattern using the Digital Operator.
Description
¬
Power ON
• Display frequency reference value.
Operation Condition Setting
• Select LOCAL mode.
-
Frequency Setting
• Change reference value.
• Write-in set value.
• Select output frequency monitor display.
®
Forward Run
• Forward run (15 Hz)
Firmware – S2011 and S3012
Revision: 1 (9/98)
Figure 15 Operation Sequence by Digital Operator
Table 10 Typical Operation by Digital Operator
Key Sequence
Change the value
by pressing
28
Digital Operator Display
0.0
REMOTE LED (SEQ. REF) OFF
\    /
15.0
/    \
15.0
0.0
15.0
RUN LED ON
LED Display
Fref
Fref
Fref
Fout
Fout
© Saftronics, Inc.