Standard Specifications - Saftronics FP5/GP5 Series Technical Manual

Table of Contents

Advertisement

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor
Chapter 9: Specifications
9.1

Standard Specifications

Series
Models
FP5/GP5
Maximum Applicable Motor
Output *(kW)
Inverter Capacity (kVA)
Rated Output Current (A)
Maximum Output Voltage
Rated Output Frequency
Rated Input Voltage and
Frequency
Allowable Voltage
Fluctuation
Allowable Frequency
Fluctuation
Control Method
Frequency Control Range
Frequency Accuracy
Frequency Resolution
Output Frequency
Resolution
Overload Capacity
Frequency Setting Signal
Accel/Decel Time
Braking Torque
Number of V/f Patterns
Motor Overload
Protection
Instantaneous
Overcurrent
Overload
Overvoltage
Undervoltage
Momentary Power Loss
Heatsink Overheat
Stall Prevention
Ground Fault
Power Charge Indication
Ambient Temperature
Humidity
Storage Temperature
Locatioan
Elevation
Vibration
∗Based on a Saftronics standard 4-pole motor for maximum applicable motor output.
Firmware – S2011 and S3012
Revision: 1 (9/98)
Table 23
200 V Class Specifications
23P7
25P5
27P5
2011
3.7
5.5
7.5
11
6.7
9.5
13
19
17.5
25
33
49
3-Phase, 200/208/220/230 V (Proportional to input voltage)
Digital Command: 0.01% (− 10°C to + 40°C)
150% of rated output current for 1 minute
0.0 to 3600 sec (Accel/decel time setting independently)
Approximately 20%
(Approximately 125% with Braking Resistor)
15 preset V/f patterns, 1 custom V/f with voltage limit, 1 custom without voltage limit
Protected by electronic Thermal Overload Relay
Motor coasts to a stop at approximately 200% of
Inverter rated current.
Motor coasts to a stop after 1 minute at 150% of
rated output current.
Motor coasts to a stop if converter output voltage exceeds 410 V.
Motor coasts to a stop if converter output voltage drops to 190 V or below.
Immediately stop by 15 ms and above momentary power loss. (Factory setting)
Continuous operation during power loss less than 2 seconds is equipped as standard.
Stall Prevention during accel/decel and constant speed operation.
CHARGE LED stays ON until bus voltage drops below 50 V.
− 10°C to + 40°C (Enclosed wall-mounted type)
Indoor (protected from corrosive gases and dust)
2
9.81m/s
(1G) at 10 to less than 20 Hz, up to 1.96m/s
FP5/GP5
2015
2018
2022
2030
15
18.5
22
30
24
30
37
50
64
80
96
130
Up to 400 Hz available by programming
3-Phase 200/208/220 V 50 Hz
200/208/220/230 V 60 Hz
+ 10%, − 15%
± 5%
Sine wave PWM
0.1 to 400 Hz
Analog Command: 0.1% (25°C ± 10°C)
Digital Operator reference: 0.1 Hz
Analog reference: 0.1 Hz
0.1 Hz
120% of rated output current for 1 minute
0 to + 10 V (20kΩ), 4 to 20 mA (250Ω)
(Braking Resistor cannot be mounted)
Motor coasts to a stop at approximately 180% of
Inverter rated current.
Motor coasts to a stop after 1 minute at 120% of
rated output current.
Protected by thermistor.
Protected by electronic circuit.
− 10°C to + 45°C (Open chassis type)
90% RH or less
−20°C to + 60°C
1000 meters or less
72
2037
2045
2055
2075
37
45
55
61
70
85
160
183
224
Approximately 20%
2
(0.2G) at 20 to 50 Hz.
© Saftronics, Inc.
75
110
300

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents