VisuNet GXP RM-GXP1100 and RM-GXP1200
Mechanical Installation
4. Prepare the other L-shaped bracket with the mounting screws.
5. Mount the prepared L-shaped bracket to the display unit housing (1), then affix both L-
shaped brackets with all screws to the stiffener frame (2).
6. Finally, tighten all the screws in a criss-cross pattern using 1.8 Nm torque for the 14x M5x25
socket head cap screws and 4 Nm for the 10x M5 lock nuts.
28
2.
1.