VisuNet GXP RM-GXP1100 and RM-GXP1200
Mechanical Installation
3.2.7
Dismounting the Display Unit
Note!
For repair purposes, the display unit can be dismounted from the computing unit (TCU or PCU)
and be replaced individually.
Warning!
Danger of Explosion
An ignition may be triggered if the computing unit is still energized when its compartment room
is opened.
Make sure the computing unit is switched off and wait 3 minutes after de-energizing before
opening the compartment room of the computing unit.
Dismounting the Display Unit
1. Open the housing (1). After de-energizing (see above), open the compartment room of the
computing unit. Then, remove all 10 screws from the back of the computing unit and take the
computing unit off from the display unit (2).
2. To ease the replacement of the display unit, temporarily affix the computing unit, e.g. by
using cable ties. To this end, put a cable tie through either mounting hole at its top left and
top right, and hang the computing unit from the top of the enclosure frame.
1
Cable Ties
1
23