Diagnostics and fault clearance
ID Dx.
Message
07 | 02 | 00129
Out of target range
(117571713)
07 | 02 | 00130
Pushback monitoring
(117571714)
07 | 02 | 00131
Residual distance too
(117571715)
low
07 | 02 | 00131
Residual distance too
(117571715)
low
Festo — CMMT-ST-SW — 2019-02
Description
Drive has left the target range
Remedy
Check target range window and recovery
time
Application monitoring reasonable? Pos-
sibly deactivate monitoring
Classifica-
Default: Warning (16)
tion
Can be parameterised: Px.4669, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Info (4)
Ignore (2)
Error
Default: save (1)
memory
Can be parameterised: Px.4670
Pushback monitoring reports error
Remedy
Check recovery time
Application monitoring reasonable? Pos-
sibly deactivate monitoring
Classifica-
Default: Info (4)
tion
Can be parameterised: Px.4671, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Info (4)
Ignore (2)
Error
Default: do not save (0)
memory
Can be parameterised: Px.4672
Residual distance too low
Remedy
none (info only)
Classifica- Default: Info (4)
tion
Can be parameterised: Px.4686, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
471