MDT Technologies SCN-P360D3.02 Technical Manual

Knx presence detector

Advertisement

Quick Links

Stand 04/2019 V1.0
Technical Manual
MDT Presence Detector
SCN-P360D3.02
SCN-P360K3.02
SCN-G360D3.02
SCN-G360K3.02
SCN-P360D4.02
SCN-P360K4.02
MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1
Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCN-P360D3.02 and is the answer not in the manual?

Questions and answers

Summary of Contents for MDT Technologies SCN-P360D3.02

  • Page 1 Stand 04/2019 V1.0 Technical Manual MDT Presence Detector SCN-P360D3.02 SCN-P360K3.02 SCN-G360D3.02 SCN-G360K3.02 SCN-P360D4.02 SCN-P360K4.02 MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 2: Table Of Contents

    4.7 Calibration of brightness value ....................36 4.7.1 Procedure for TeachIn with constant light control .............. 38 4.7.2 Procedure for teach-in without constant light control ............39 MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 3 6 Attachment ............................55 6.1 Statutory requirements ....................... 55 6.2 Routine disposal .......................... 55 6.3 Assemblage ..........................55 6.4 Datasheet ............................ 56 MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 4: Overview

    This can control up to 3 light bands in a way to hold the brightness in a room continuously at a constant value. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 5: Exemplary Circuit Diagram

    4 pyro sensors. The LEDs are marked with R for the red LED and G for the green LED. The bus connector is marked with BC: Figure 2: Position of the sensors and LEDs – SCN-P360X4.02 MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 6 60 cm to the next lamp and in the line of the middle light band. The following figures show the detection area of the presence detectors: Figure 4: Detection area SCN-P360x4.02 MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 7 Technical Manual Presence Detector SCN-P/G360XX.02 Figure 5: Detection area SCN-P360x3.02 MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 8: Functions

    Calibration of brightness value The correction of the measured brightness value can be adjusted by a steady parameter or via the Teach-In object. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 9: Settings In The Ets-Software

    (5) Loading of the application, with requested parameterization (6) If the device is enabled you can test the requested functions (also possible by using the ETS- Software) MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 10: Communication Objects

    Day/Night toggle Day = 0 / Night = 1 1 Bit Day/Night toggle Day = 1 / Night = 0 1 Bit MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 11 C stands for communication, R for reading, W for writing, T for transmission, and U for updating. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 12: Reference Ets-Parameter

    Technical Manual Presence Detector SCN-P/G360XX.02 4 Reference ETS-Parameter 4.1 General Settings The following figure shows the submenu for the general settings: Figure 6: General Settings MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 13 C li al se di g heart eat  Activation of a cyclic not active  1min – 24h "heartbeat" telegram Table 2: Parameter - General Settings MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 14 Switchover between day and night mode Se di g of a heart eat telegra Output heartbeat 1 Bit Table 3: General communication objects MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 15: Light Channel 1/2/3/4/Hcv

    "1" to the object "Dark". Independent of brightness: The light channel switches independently of the measured brightness MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 16: Channel Mode Selection

    In half automatic mode, the output is switched on via the "External push-button short" object and is automatically switched off again after the follow-up time has expired.. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 17: Follow-Up Time

    MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 18: Force Or Lock Object

     Lock (current state) The light channel is locked in its current state and remains locked until the locking process is deactivated.. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 19: Output Object

    MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 20 Light channel 1 – Output 2 - 1 Bit Second switching function of the light channel Switching Table 9: Communication objects - Output object "Dimming absolute" MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 21 Output object 1 (depending on the parameterisation Switching, absolute dimming or scene) can send the parameterised value cyclically. In addition, the second switching object can also send its value cyclically. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 22: External Push Button Input

    The idle time after switching off defines the time that the presence detector is blocked for further detection after the follow-up time has elapsed. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 23: Process Diagram

    General settings menu – Release time for push button. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 24 The light is then switched off and the light channel changes to the "Auto mode, ready" state. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 25 The output is then switched to the orientation light state and can therefore dim the light to a darker level in order to leave the room safely. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 26 The light channel can also be overridden via the "external push-button - short" object. The motion detector can be switched to manual mode by pressing twice MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 27 The output is then switched to the orientation light state and can therefore dim the light to a darker level in order to leave the room safely. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 28: Master/Slave Operation

    "1" sent to the master, the master's follow-up time expires before it switches off its output. In this case, the follow-up time from master and slave is added. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 29: Alarm

    1234 Release sensitivity for Adjustment of sensitivity for triggering Day/Night [3 (Day), 2 (Night)] the alarm in standby mode (no motion detected) MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 30 2 sec, at least one detection in the second 2s and at least one detection in the third 2 sec. Thus it takes at least 6 seconds until the alarm channel is triggered. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 31 1 Bit Locking the alarm function Alarm Input – Enable 1 Bit Enabling the alarm function Table 14: Communication objects - Alarm function MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 32: Led

    Setting whether the green LED for this not active  channel should signal a detected active movement Table 15: Settings Submenu - LED MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 33: Scenes

    The following table shows the corresponding communication objects: Number Name Length Usage Scene – Input 1 Byte Call up of the scene Table 17: Communication objects - Scene MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 34: Brightness

     Object value at Day and Setting the polarity  exceedance  Object value at Night and Setting the polarity  exceedance MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 35 1 Bit sends the set value at exceedance/shortfall Status brightness value 2 Byte measured brightness value Table 19: Communication objects - Brightness MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 36: Calibration Of Brightness Value

    Thus, at a set value of -50%, the measured value is reduced by 50%. Thus the presence detector would output the value 200 at a measured value of 400 lux and a correction value of -50%. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 37 The procedure for the TeachIn with constant light control (SCN-P360K3.02 and SCN-P360K4.02) is described in the following chapter, the TeachIn procedure for presence detectors without constant light control (SCN-P360D3.02 and SCN-P360D4.02) is described in the next but one chapter. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1...
  • Page 38: Procedure For Teachin With Constant Light Control

    , the switch on value is calculated automatically now. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 39: Procedure For Teach-In Without Constant Light Control

    6. Now the presence detector has adopted the adjusted value as new measurand and corrects its measurement from now according to the TeachIn value. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 40: Constant Light Control

    The following figure shows the possible settings for the general constant light control settings: Figure 24: General settings - Constant light control MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 41 Alternatively, the presence detector can also be moved further into the centre of the room. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 42 The new "proportional master/slave constant light control" eliminates all the disadvantages of the standard "offset master/slave constant light control" with fixed offset.. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 43 (Wall x1,6, Window x0,7) high (Wall x1,8; Window x0,6) very high (Wall x2; Window x0,5) Window Main Wall Figure 26: Influence control parameters MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 44: Setting Options

    4.8.2 Setting Options The following figure shows the available specific settings for the constant light control: Figure 27: Setting options - constant light control MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 45 Relative dimming time defines the time for dimming [20 s] from 0 to 100% Table 24: Setting options - Constant Light Control / 1 MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 46 Teach-In procedure or to have the switch-on value calculated directly internally. The time until the control starts after switching on can also be defined. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 47 Output for wall group Output dimming absolute 1 Byte Output for window group window Table 26: Communication objects - constant light control MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 48: Logic

    The parameter "Request inputs after bus power reset" defines whether the external inputs of the logic should be queried after a restart. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 49: Logic 1-4

    Setting of the logic function    Output object Setting the output object for the logic Switching  Scene  Value  Force 2bit MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 50 Output of the logic function; size and DPT 2 Bit/ dependent on the parameter Output object 1 Byte Table 28: Communication objects - Logic MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 51: Temperature

    The following table shows the available communication object: Number Name Length Usage Temperature – Measured 2 Byte Sending the measured value value Table 29: Communication object - Temperature measurement MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 52: Miscellaneous/Application Examples

    The o je t e ter al i put of the se o d light group eeds to e o e ted to the push utto , which sends the requirement for the blackboard light. The push button has to send an 1-signal to the object. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 53: Index

    Figure 28: Activation of Logic function ....................48 Figure 29: Submenu - Logic ........................49 Figure 30: Settings - Temperature measurement ................. 51 MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 54: List Of Tables

    Table 27: Parameter settings - logic function ..................50 Table 28: Communication objects - Logic....................50 Table 29: Communication object - Temperature measurement ............51 MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 55: Attachment

    All activities on the device should only be done by an electrical specialist. The county specific regulations and the applicable EIB-directives have to be observed. MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 Tel.: +49-2263-880 • Fax: +49-2263-4588 • knx@mdt.de • www.mdt.de...
  • Page 56: Datasheet

    Light sensor (Presence max. 8m) SCN-P360K4.02 Presence Detector, 4 pyro detectors Light sensor, constant level light intensity (Presence max. 8m) SCN-P360D3.02 Presence Detector, 3 pyro detectors Light sensor (Presence max. 5m) SCN-P360K3.02 Presence Detector, 3 pyro detectors Light sensor, constant level light intensity (Presence max. 5m) SCN-G360D3.02 Glass Presence Detector, White, 3 pyro d.
  • Page 57 43mm x 43mm x 30mm * at maximum mounting height of 4m (See images below). Covered area SCN-P360x4.02 Covered area SCN-x360x3.02 Examplary circuit diagram SCN-x360xx.02 Covered area SCN-P360x1.01 MDT technologies GmbH DIN EN ISO 9001 • • 51766 Engelskirchen Papiermühle 1 TAW Cert Tel.: + 49 - 2263 - 880...

Table of Contents