Download Print this page

YASKAWA VU*B****AA*-134 Series Manual page 11

V1000 option 1000 hz high frequency custom software

Advertisement

Parameter
A1-02
b4-01
b4-02
b5-20
H6-01
L3-02
L3-04
o1-03
Parameter
b2-04
DC Injection Braking Time at Stop
n1-01
Hunting Prevention Selection
Parameter
S1-01
On-Delay Compensation Selection
YASKAWA ELECTRIC TM.V1000SW.134A 1000 Hz High Frequency Custom Software Supplement
Table 5 Modified Parameter Setting Ranges
Control Method Selection
Timer Function On-Delay Time
Timer Function Off-Delay Time
PID Setpoint Scaling
Pulse Train Input Terminal RP Function Selection
Stall Prevention Level during Acceleration
Stall Prevention Selection during Deceleration
Digital Operator Display Selection
Table 6 Parameters with Modified Defaults
Name
Table 7 New Parameter
Name
Name
Setting Range
Default
0.0 ~ 10.0
0.0 s
0, 1
0 (off)
Setting Range
Default
0, 1
4 Modified Parameters
Setting Range
0.0 ~ 3000.0 s
0.0 ~ 3000.0 s
0, 1, 3
0, 1, 2
0 ~ 170%
0, 1, 3
Note
Previous default: 0.5
Previous default: 1 (on)
Note
1
0: Disabled, 1: Enabled
0
0 ~ 3
11

Advertisement

loading

This manual is also suitable for:

Vu*b****ba*-134 seriesVu*b****fa*-134 series