Procedure For Time Code Synchronization - Sony Digital betacam DVW-970 Operation Manual

Sony digital camcorder operation manuals dvw-970, dvw-970p
Hide thumbs Also See for Digital betacam DVW-970:
Table of Contents

Advertisement

Example 2: Interconnecting a number of camcorders
for time code synchronization
TEST OUT
TC OUT
TC IN
1)
GENLOCK IN
TC OUT
TEST OUT
1)
GENLOCK IN
TC IN
TC OUT
TEST OUT
To another camcorder to be synchronized
1) Set GENLOCK to ON on the GENLOCK page of the
MAINTENANCE menu, if GENLOCK is set to OFF.

Procedure for time code synchronization

To synchronize the time code, proceed as follows:
1
2
Synchronizing the time code
1
Turn on the POWER switch.
2
Set the PRESET/REGEN/CLOCK switch to PRESET.
3
Set the F-RUN/SET/R-RUN switch to F-RUN.
4
Set the DISPLAY switch to TC.
5
Supply a time code signal and a reference video signal
complying with the SMPTE (for the DVW-970) or
EBU (for the DVW-970P) standard and in proper
phase relationship, to the TC IN connector and to the
GENLOCK IN connector, respectively.
Reference camcorder
4
3
This operation synchronizes the internal time code
generator with the external time code. After about 10
seconds, you can disconnect the external time code
without losing the synchronization. However, there
will be noise on the recorded image if you connect or
disconnect the time code signal during recording.
Notes
• When you finish the above procedure, the internal time
code is immediately synchronized with the external time
code and the counter display will show the value of the
external time code. However, wait for a few seconds
until the sync generator stabilizes before recording.
• If the frequency of the reference video signal is not the
same as the frame frequency of the camcorder, the
camera cannot be correctly genlocked. In such a case, the
internal time code is not correctly synchronized with the
external time code.
• When the GENLOCK ON/OFF item is set to "OFF" on
the GENLOCK page of the MAINTENANCE menu, the
time code cannot be synchronized with the reference
video signal. In this case, set the GENLOCK item to
"ON" on the GENLOCK page of the MAINTENANCE
menu.
User bit settings during time code
synchronization
When the time code is synchronized, only the time data is
synchronized with the external time code value. Therefore,
the user bits can have their own settings for each
camcorder.
To synchronize the user bits with external user bit data, set
the EXT-LK UBIT item on the TIME CODE page of the
MAINTENANCE menu to "EXT."
To release the time code synchronization
First disconnect the external time code, then set the F-
RUN/SET/R-RUN switch to R-RUN.
To change the power supply from the battery
pack to an external power supply during time
code synchronization
To maintain a continuous power supply, connect the
external power supply to the DC IN connector before
removing the battery pack. You may lose time code
synchronization if you remove the battery pack first.
Camera synchronization during time code
synchronization
During time code synchronization, the camera is
genlocked to the reference video signal input from the
GENLOCK IN connector.
69
Setting the Time Data