Hellenbrand H-200M Series Owner's Manual page 16

Water conditioning system
Table of Contents

Advertisement

AUXILIARY INPUT
STEP 15CS
ON 0
REG
SET
BACKWASH
STEP 16CS
CYCLE 1
SET
REGENERANT DRAW DN
STEP 17CS
CYCLE 2
SET
BACKWASH
STEP 18CS
CYCLE 3
SET
RINSE
STEP 19CS
CYCLE 4
SET
FILL
STEP 20CS
CYCLE 5
SET
END
STEP 21CS
CYCLE 6
SET
ALT FILL TRIGGER
STEP 22CS
REGENS
OFF
SET
ALT FILL AMOUNT
STEP 23CS
15.0
LBS
SET
16
STEP 15CS – This display will be available to select the use of an outside signal to control the initiation
of a regeneration. Selection only matters if a connection is made to the two pin connector labeled DP
SWITCH located on the printed circuit board. Following is an explanation of the options:
• ON 0 REGEN – If the dP switch is closed for an accumulative time of 2 minutes, a regeneration will
occur immediately.
• DELAY REGEN – If the dP switch is closed for an accumulative time of 2 minutes, a regeneration will
occur at the schedule regeneration time.
• HOLD REGEN – If the dP switch is closed a regeneration will be prevented from occurring.
• OFF - Factory setting is off
Press NEXT to go to Step 16CS. Press REGEN to return to previous step.
STEP 16CS – Press the  or  buttons until selection of first cycle appears in left upper corner, in this ex-
ample BACKWASH is selected. Press NEXT to go to Step 17CS. Press REGEN to return to previous step.
STEP 17CS – Press the  or  buttons until selection of second cycle appears in left upper corner, in
this example Regenerant Draw DN is selected. For a H125 control valve: prior to selecting DN or UP or
not selecting a regenerant flow cycle, verify the correct valve body, main piston, regenerant piston and
stack are being used and the injector or injector plug(s) are in the correct location. Press NEXT to go to
Step 18CS. Press REGEN to return to previous step.
STEP 18CS – Press the  or  buttons until selection of third cycle appears in left upper corner, in this
example BACKWASH is selected. A second backwash mode is recommended on iron
applications > 1.0 ppm. Press NEXT to go to Step 19CS. Press REGEN to return to previous step.
STEP 19CS – Press the  or  buttons until selection of fourth cycle appears in left upper corner, in
this example RINSE is selected. Press NEXT to go to Step 20CS. Press REGEN to return to previous
step.
STEP 20CS – Press the  or  buttons until selection of fifth cycle appears in upper left corner. Press
NEXT to go to Step 21CS. Press REGEN to return to previous step.
STEP 21CS – Press the  or  button until last regeneration cycle; END appears (up to 9
regeneration modes are possible). End must be selected as last cycle. Press NEXT to go to Step
22CS.
STEP 22CS – Press the  or  button to select number of standard regenerations which would trigger
one alternate brine fill amount. Range: 1-99. Factory setting is Off. Press NEXT to go to Step 23CS.
STEP 23CS – Select amount of salt to be used when alternate regeneration requested. This screen is
not displayed if off is selected in previous step. Softener Range 0.1–200 lbs. Filter Range 0.05–20.0
Gallons.