DRAW TIME
68:00
SET
MIN
RINSE TIME
6:00
SET
MIN
FILL
50.0
MIN
SET
GRAIN OF CAPACITY
168
SET
x1K
NORMAL
FILL
SET
RESERVE CALCULATOR
AUTO
SET
DELAY + IMMEDIATE
STEP 10S
REGEN
SET
STEP 11S
RELAY 1 "TIME"
TRIGGER
SET
Figure 12a
10
STEP 4S – Select the time for the second cycle (which in this example is down BRINE) using
STEP 4S
the  or  button. (Range: 1-180 minutes). Press NEXT to go to Step 5S. Press REGEN to
return to the previous step.
STEP 5S – Select the time for the third cycle (which in this example is RINSE) using the  or
 button. (Range: 1-120 minutes). Press NEXT to go to Step 6S. Press REGEN to return to the
previous step.
STEP 6S – Select the time for the fourth cycle (which in this example is FILL, setting is changed
STEP 5S
by lbs. of salt entered) using the  or  button. (Range: 0.1-99 minutes). Factory setting is Medium
Salting, See page 34-35. Press NEXT to go to Step 7S. Press REGEN to return to previous step.
STEP 7S - Set Grain Capacity using the  or  button. The ion exchange capacity is in grains of
hardness as calcium carbonate for the system based on the pounds of salt that will be used. The
allowable grains capacity range varies from 5,000 to 3,000,000 grains. The increment increase
is 500 for the range from 5000 to 30,000; 1000 for the range of 30,000 to 100,000; 2000 for the
range of 100,000 to 200,000; 5,000 for the range of 200,000 to 500,000; and 20,000 for the range
STEP 6S
of 500,000 to 3,000,000. Grains capacity is affected by the fill time. The grains capacity for the
selected lbs. salting should be confirmed by testing. The capacity and hardness levels entered
are used to automatically calculate reserve capacity when gallon capacity is set to AUTO. Factory
setting is the capacity of the softener at medium salting. See Page 34-35. Press NEXT to go
to Step 8S. Press REGEN to return to previous step.
STEP 8S – Select between proportional or normal brining. Screen will not appear unless valve
is configured as upflow and prefill. Use  or  buttons to select. Proportional brining will divide
STEP 7S
the actual gallons used by calculated volumetric capacity then multiply fill volume by this percent-
age. This option requires a functioning meter. Factory Setting = Normal brining. Press NEXT to
go to Step 9S. Press REGEN to return to previous step.
STEP 9S – Set Gallons Capacity using  or  button. If value is set to:
• "AUTO" gallon capacity will be automatically calculated and reserve capacity will be automatically
estimated;
• "oFF" regeneration will be based solely on the day override set (see Installer Display/Settings
STEP 8S
Step 3, page 8 / proportional brining will not function if OFF selected); or
• as a number of gallons (allowable range 20 to 1,500,000) regeneration will be based on the value
specified.
Increment increase is 20 for the range 20 to 2000, 100 for the range of 2000 to 10,000 and 500 for
the range of 10,000 to 50,000 and 2000 for range of 50,000 to 1,500,000.
If "oFF" or a number is used, hardness cannot be set in Installer Displays/Settings Step 2 I, page
8. See pages 34-35 for more detail. Factory Setting is AUTO. Press NEXT to go to Step 10 S.
Press REGEN to return to previous step.
STEP 9S
STEP 10S – Set Regeneration Time Options using the  or  button. If value is set to:
• "DELAY" means regeneration will occur at the preset time;
• "IMMEDIATE" means regeneration will occur immediately when the gallons capacity reaches 0
(zero); or
• "DELAY + IMMEDIATE" means regeneration will occur at one of the following:
- the preset time when the gallons capacity falls below the reserve or the specified number of days
between regenerations is reached, whichever comes first; or
- immediately after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).
See page 36 for more options. Factory Setting is DELAY + IMMEDIATE. Press NEXT to go to
Step 11S. Press REGEN to return to previous step.
STEP 11S – Set Relay to activate by Time, Gallons, Regen Gallons, Off, Service Alarm or
Lockout by using  or  buttons. A relay can be used to operate a chemical feed pump or sole-
noid ect. The choices are:
• Relay Triggered on Time - Relay activates after set number of minutes after start of regeneration.
Start of regeneration is defined by first backwash cycle, dn brine or up brine, whichever is
first. Relay deactivates after set time. If time selected as trigger, press NEXT for 12S.
• Relay Triggered on Gallons - Relay activates every set number of gallons while in service and
deactivates after set time. If gallons selected as trigger, press NEXT for 15S.
• Relay Triggered on Regen Gallons - Relay activates after set number of gallons in service or gal-
lons used during regeneration and de-activates after set time or when meter stops registering
flow, whichever comes first. If regen gallons selected, press NEXT for 18S.
• Relay Triggered for Lockout - Relay closes at set time before or after start of regeneration. A
negative start time delays regeneration by that amount of time. Selection of energizing relay
for complete regeneration cycle is available by selecting REGEN for time setting, see step 22S.
• Service Alarm - Relay activates on service alarm setting: gallons, time or both, see step 20S.
• Off - If off is selected, Steps 14S – 22S will not be shown. Factory setting = OFF. Press
NEXT to go to step 12S for other selection for relay settings, or 24S if OFF selected.