Anytime cycle sequence is modified, softener set-up will revert to manufacturer
setting and must be reprogrammed as desired.
Cycle Sequence instructions allows the operator to set the order of the cycle. The
Softener System Setup allows the operator to set how long the cycles will last. The
operator may choose up to 9 cycles in any order.
END must be used as the last cycle option. The SOFTENING cycle should only be
used in brine prefill applications to allow salt to dissolve.
See Step 16CS for an example of how to set a valve so that when regeneration is initiated, BACKWASH occurs first, REGENERANT DRAW
DN occurs second, SECOND BACKWASH occurs third, RINSE occurs fourth and FILL occurs fifth.
STEP 1CS
VALVE TYPE
2.0
STEP 2CS
SET
METER SIZE
STEP 3CS
2.0
IN
SET
ALTERNATOR SYSTEM
STEP 4CS
OFF
SET
ALTERNATOR SYSTEM
ALT A
SET
13
CYCLE SEQUENCE
STEP 1CS – Press NEXT and  simultaneously until display changes. Then release & press NEXT and
 simultaneously again for 3 seconds and release. If screen in step 2CS does not
appear in 5 seconds the lock on the valve is activated.
STEP 2CS – Valve Type. Use the  or  to select from 1.0", 1.25", 1.50", 2.0L", 2.0" valve.
H200M is a 2.0" valve. Press NEXT to go to Step 3CS.
STEP 3CS – Meter Size. This display is only viewed when 2.0" or 2.0L" is selected in Step 2CS. Use the
 or  to select meter size.
STEP 4CS – Use the  or  to select one of the following:
• Twin Alternating System – Select Alt A or Alt B, See instructions in Step 5CS; or
• System Board - Allows Demand Recall Programming – See instructions in Step 10CS.
• No Hard Water Bypass During Regeneration – See instructions in Step 7CS.
• Reclaim Enabled - Allows control to operate in Reclamation Mode – See instructions in Step 9CS.
• Separate Source Enabled - Allows control to have a separate water source during the
regeneration cycle. See instructions in Step 8CS.
• OFF; Factory Setting is OFF - Press NEXT to go to Step 11CS.
STEP 5CS –Twin Alternating System – Allows automatic alternation between two units to pro-
STEP 5CS
vide softened water 24 hours a day.
Use  or  buttons to select ALT A or ALT B
Select ALT A for the control valve that has the two-pin connector labeled MAV DRIVE connected
to the alternator valve.
Select ALT B for the control valve that will be connected via three-prong connector labeled IN-
TERCONNECT. Must use 3-wire interconnect cable. Press NEXT to go to Step 6CS.
For Alternating System, change programming:
• Set softener, with volume capacity in GALLONS and select
Regeneration Time Option "IMMEDIATE" or "DELAYED" and select DAYS
BETWEEN REGEN as desired.
• For complete programming, see Twin Alternating MAV manual.
Cycle Options
REGENERANT
BACKWASH
DRAW
RINSE
SOFTENING
FILL
END