RELAY 1 SERV ALARM
TRIGGER
SET
RELAY 1 LOCKOUT
TRIGGER
SET
RELAY 1 SETPOINT
SET
RELAY 1 DURATION
70:00
SET
RELAY 2 TRIGGER
REGEN
GAL
SET
SERVICE ALARM
STEP 25S
BOTH
SET
SCHEDULED SERVICE
STEP 26S
0.25
YR
SET
SCHEDULED SERVICE
STEP 27S
80000
GAL
SET
RETURN TO NORMAL MODE
12
STEP 20S –
Service Alarm chosen to activate relay, relay closes whenever Service Alarm
STEP 20S
has triggered. Programming for relay closure on service reminder is done on Step 25S. Relay
opens when service alarm reset. Press NEXT to go to Step 24S to set Relay 2 Settings. If off
selected for Relay 2, service reminder programming on Step 25S.
• Relay closes on Gallons
• Relay closes on Time
• Relay closes on Both
• Off, Factory setting is off
STEP 21S –
Relay Triggered for Lockout, relay closes at set time before or after start of
STEP 21S
regeneration, activation time is referenced to start of backwash or draw, whichever is first. Relay
remains activated during error mode, after power failure and after manual advance. If manually
advancing through regeneration, reset by holding NEXT/REGEN buttons after regeneration is
complete to deactivate relay. Press NEXT to Set Start Time.
STEP 22S
-20
MIN
STEP 23S
MIN
STEP 24S –
Relay 2 programming includes identical options as Relay 1, with the addition of the
STEP 24S
ability to energize Relay 2 in the event an error occurs. Press NEXT to go to Step 25S.
SERVICE REMINDER
STEP 25S – Set scheduled service display using  or  buttons. Available options are OFF, TIME,
ON GAL or BOTH. Selecting OFF disables this feature. If OFF is selected, press NEXT to exit
System Setup. If TIME, ON GAL or BOTH is selected press NEXT to select the TIME and/or ON
GAL values. See Steps 26S and/or 27S. When days fall less than 1 year, display shows "sched-
uled service in xxx days". Service technician can program if desired. This can also activate relay if
Service Alarm is selected on Step 20S. Press REGEN to return to the previous step.
STEP 26S – Service alarm for TIME ranges from 0.25 to 9.75 years. Use  and  buttons to set.
Press NEXT to either exit System Setup or if BOTH was selected go to Step 27S. When number
of days drops below 1 year, display in OEM program displays "scheduled service in xxx days" in
screen right after service remainder is programmed. Press REGEN to return to the previous step.
STEP 27S – Service alarm for ON GAL ranges from 100 to 9,999,900 gallons. Use  and  to set.
Press NEXT to exit System Setup. Press REGEN to return to the previous step.
Reset service reminder by holding down up and down arrows together when reminder is
displayed.
STEP 22S –
Use up or down arrows to select start time into regeneration to
energize relay (regeneration is defined by start of backwash or draw; whatever
comes first).
Range = -20 – 500 minutes or select REGEN. A negative start time delays re-
generation by that amount of time. Select REGEN if relay activation is desired for
complete regeneration. When REGEN selected for lock-out, 2 min delay is built
in prior to MAV movement. Access REGEN by pushing down button through all
negative numbers. Press NEXT to select duration of relay activation.
STEP 23S –
Use up or down arrows to select duration of relay activation.
Range = 0:01 (1 second) - 500:00 (500 minutes). Press NEXT to go to Relay 2
programming.