Confi guring the Control Valve for Reclamation Mode:
STEP 9CS – Configuring the Control Valve for Water Reclamation Mode - Select Reclamation Enabled for control operation. Motorized
Select Reclaim Enabled for control operation. Motorized Alternating Valve will advance to Bypass at a set time after the beginning of
Alternating Valve will advance to Bypass at a set time after the beginning of regeneration, and return to Service after a set duration. Up to three
regeneration, and return to Service after a set duration. Up to three bypass events are possible. From the SET screen, pressing SET
bypass events are possible.
CLOCK will increase the number of reclaim cycles up to 3.
From the RECLAIM ENABLED screen, up to 3 reclamation cycles are possible, use up arrow to select reclaim enabled for one reclaim event,
From the RECLAIM ENABELD screen, pressing the SET CLOCK button will increase the number of reclamation cycles, up to 3. The
reclaim 2x for two reclaim events and 3x for three reclaim events. The Alternating MAV transitions to Bypass at the set time after the start of
Alternating MAV transitions to Bypass at a set time after the start of regeneration. The start of regeneration is defi ned as the fi rst cycle
regeneration. The start of regeneration is defined as the first cycle that is not FILL, SOFTENING or FILTERING. The Alternating MAV will transi-
that is not FILL, SOFTENING or FILTERING. The Alternating MAV will transition back to Service after the completion of the preset
tion back to Service after the completion of the preset duration time.
duration time.
STEP 9CS
14
Confi guring the Control Valve to operate with Clack System Controller:
Select System Board Enabled to link the Control Valve to the Clack System Controller. For
STEP 6CS – Select Twin Alternating Option.
STEP 6CS
MIN
Use  or  buttons to select
• Standard - Standard Alternating Function
• Refresh Rinse - Alternates every 6am & 6pm and runs programmable number of gallons to
service. Press NEXT to set number of gallons.
• Delayed Rinse and Fill- See below
• Factory Setting is Standard Alternating Function
This option delays the last two cycles of regeneration (only "Rinse" and "Fill"). This feature
splits the regeneration into two portions. The first portion of the regeneration will start imme-
diately and all programmed cycles before the "Rinse" and "Fill" cycles will be performed. After
all programmed cycles before "Rinse" and "Fill" are completed the control valve will drive to the
service position (displaying "Delayed Rinse + Fill Pending"). When the volume of the on-line
unit is depleted to 10% of its programmed capacity, the control valve will be triggered to finish
the second portion of the regeneration and complete the "Rinse" and "Fill" cycles and return to
Service and be placed into Standby mode, and wait to come on-line for service. Press NEXT to
go to Step 11CS.
STEP 7CS – No Hard Water Bypass Enabled - Use  or  buttons to select NO HARD
STEP 7CS
WATER BYPASS ENABLE. Selection requires that a connection to a Motorized Alternator Valve
(MAV) is made to the two pin-connector labeled ALTERNATOR MAV DRIVE located on the
printed circuit board. The MAV will be driven closed before the first regeneration cycle that is
not FILL or SOFTENING or FILTERING, and be driven open after the last regeneration cycle
that is not FILL. NOTE: If the control valve enters into an error state during regeneration mode,
the no hard water bypass valve will remain in its current state until the error is corrected and
reset. Reset by pushing NEXT & REGEN buttons simultaneously until display changes. MAV
gear out for service, MAV gear in for bypass. Press NEXT to go to Step 11CS.
STEP 8CS – Configuring the Control Valve for Separate Source Operation - Select Sepa-
STEP 8CS
rate Source Enabled for control operation. For separate source operation, the three wire connec-
tor is not used. Selection requires that a connection to a MAV is made to the two pin connector
labeled ALTERNATOR MAV DRIVE located on the printed circuit board. The C port of the MAV
must be connected to the valve inlet and the A port connected to the separate source used dur-
ing regeneration. The B port must be connected to the feed water supply. When set to Separate
Source Enabled the MAV will be driven closed before the first regeneration cycle, and be driven
to open after the last regeneration cycle.
NOTE: If the control valve enters into an error state during regeneration mode, the MAV will
remain in its current state until the error is corrected and reset. Reset by pushing NEXT &
REGEN buttons simultaneously until display changes. MAV gear out for service, MAV gear in
for bypass.