Forced checking procedure
The maximum value for the forced checking procedure interval when using option K82 is
6 months (4380 h).
Customer interface -X41
Table 5- 3
Terminal strip -X41
Terminal
Meaning
-X41:1
Control of -K41:A1
-X41:2
Connected to -X41:1
-X41:3
Control of -K41:A2, -K42:A2 , N conductor or
ground
-X41:4
Connected to -X41:3
-X41:5
Feedback signal, status -K41, -K42
-X41:6
Feedback signal, status -K41, -K42
-X41:7
Control of -K42:A1
-X41:8
Connected to -X41:7
-X41:9
Connection of optional checkback
-X41:10
Output -K41: Permanently wired with
CU320-2: -X132:4 (DI 7)
Safety Integrated
Function Manual, 07/2016, A5E03264275A
5.2 Control of "STO" and "SS1" via terminal module for option K82
Technical data
Connection for actuating element at channel 1 "+"
Connection for actuating element at channel 1 "+", for inter-
connecting Motor Modules in groups
Connection of reference potential for actuating elements at
channel 1 and channel 2
Connection of reference potential for actuating elements at
channel 1 and channel 2, for interconnecting Motor Modules
in groups
Connection of supply voltage for optional feedback signal
Connection for optional checkback signal, for interconnect-
ing Motor Modules in groups
Connection for actuating element at channel 2 "+"
Connection for actuating element at channel 2 "+", for inter-
connecting Motor Modules in groups
For the option of connecting other checkback signals in
series when Motor Modules are grouped
Output -K41: For connecting to a digital input according to
the Safety settings on the CU320-2 (already wired in option
K90)
Controlling the safety functions