Electrical connections
Replace power cable
The replacement of the cable must be performed by authorized personnel. The earthing must be yellow
and green.
To replace the power supply cable (if using a terminal board with a pre-installed cable), proceed as follows:
• Open the terminal board cover by removing the fixing screws
• Connect the wires in accordance with the selected connection diagram
• Secure the cable using the relevant cable clamp
• Close the terminal board cover and tighten the fixing screws
Caution!
The power supply cable may only be replaced by the manufacturer, a representative from the Assistance
Service or a similarly qualified member of staff.
Incorrect connection may cause the terminal board to overheat so much that it melts.
In light of the above information, UNOX accepts no responsibility for any situation resulting from work carried
out in an unprofessional manner, or from the incorrect interpretation or application of regulations.
The appliance must be connected to the electricity mains earth conductor.
Equipotential connection
The appliance must be included in an equipotential system, which has been checked for efficiency in accordance
with the specifications set out in current regulations.
This connection must be performed between different appliances, using the terminal marked as equipotential.
The equipotential wire must have a minimum cross-section of 10 mm2 and must be yellow and green.