Post-connection checks

Check the items listed in the table after connecting the oven to the gas supply or after adjusting to a new type
of gas.
Check:
The air-tightness of the gas circuit using NON-CORROSIVE foam substances.
Never use flames!
contact the local gas supply company .
The gas valve outflow pressure.
Compare values with those of " Table D - Gas valve outflow pressure"
31
The values of CO - CO
burner settings must be checked and adjusted by a specialised technician for
values of non-diluted CO greater than 1000 ppm.
If the tests were positive, power and start-up the appliance, and through the air vents, check the points listed
in the table:
Checks:
Proper burner ignition
Bright blue flame with no yellow tips
Gas exhaust pipe and air vents clean and free of obstructions
Instruct the user about the basics of safe oven operation with respect to this installation, use and maintenance
manual.
CHART A
of the exhaust gas and record values detected. The
2
31
ChefTop
Check result
mbar.........................
min mbar................
max mbar................
ppm.........................
Check result - OK