Debug System; Ocds1; Dap - Infineon TC3X7 ADAS Manual

Application kit
Table of Contents

Advertisement

Application Kit Manual TC3X7 ADAS
Hardware: Application Kit TC3X7 ADAS V2.0
Application Kit Information
The WAKE button (S102) will be used to enable/wakeup the TLF3068x.
3.17

Debug System

3.17.1

OCDS1

The OCDS1 signals are connected to the IDC16 plug (X401). They work with the port supply of Microcontroller (+5V
default or +3,3V). For pinout of the connector see
The signals /BRKIN and /BRKOUT are not connected.
If you connect a debug hardware make sure that the miniWiggler JDS (see
activ (ACTIV LED is off) and on the DAP connector (X302) is no hardware connected or the hardware is tristated.
If the ACTIV LED is on, then stop the active DAS Server 'UDAS' and/or remove the USB connection to the PC.
3.17.2

DAP

The board comes with a DAP connector (X302). For pinout of this connector see
hardware here. If you use this connector make sure that the miniWiggler JDS is not activ (ACTIV LED is off) and a
connected OCDS1 hardware is disconnected or tristated.
User Manual
Application Kit TC3X7 ADAS V2.0
Figure
6-8. You can connect any debugger to this connector.
3-6
"miniWiggler JDS" on Page
Figure
6-9. You can connect a DAP
3-4) is not
V2.0