SPECIFICATIONS FOR PART 5.3 COMPLIANCE

PART 1 GENERAL
1.01 SUMMARY
A. The product described herein, manufactured by
Savaria is an elevator designed and dimensioned
to provide Limited Use/Limited Application (LULA)
elevator to suit individual building requirements
for use by persons with disabilities.
1.2 REFERENCES
A. Elevator shall be designed, manufactured and
installed in accordance with the following standards:
1. American National Standards Institute (ANSI).
2. American Society of Mechanical Engineers (ASME).
3.National Electrical Code (NEC)
Canadian Electrical Code (CEC)
4. American Society for Testing Materials (ASTM).
5. American Welding Society (AWS).
Canadian Welding Bureau (CWB)
1.3 SYSTEM DESCRIPTION
A. 5 hp submersed motor and pump with electronic
proportional valve assembly; Programmable logic
controller with collective operation; 1:2 roped hydraulic
single stage cylinder with line rupture valve.
B. Number of Stops:
(specify:)
C. Car Confi guration:
(specify:)
90° side exit or enter/exit same side.
D. Maximum Travel:
(specify:)
E. Rated Load:
(specify:)
1400 lbs. (635 kg)
F. Rated Speed: 30 fpm (.15m/s)
G. Car Size:
1. 48" x 54" (1219 mm x 1372 mm) platform (standard)
2. 84" (2134 mm) high ceiling
H. Car Walls:
(specify:)
Steel panels (black or
architectural white)with (optional) raised plastic
laminate panels (contact Savaria for colors).
I. Car Ceiling: White panel.
J. Car Lighting: Four recessed lights.
K. Operating Features:
1. Car Operating Panel:
(specify:)
stainless steel or brushed brass panel with
illuminated automatic controls, keyed light switch,
emergency stop switch and alarm button
2. Hall Stations:
(specify:)
brushed brass panel with illuminated button and
(specify option:) key lock provided at each landing.
3. Car Door(s): Fully automatic, side opening,
sliding car door with electromechanical interlocks,
obstruction sensor, and automatic re-open system.
4. Hoistway Doors: 1 ½ hour fi re rated fully
automatic side opening, sliding hoistway
doors with two side opening panels in steel
frame with electromechanical interlocks.
5. Handrail:
(specify:)
Stainless steel or brass.
6. Pit Switch
Page 26 of 27
Orion Planning Guide
Two to Four.
straight-thru,
Up to 25' (7.62 m)
Brushed
Brushed stainless steel or
7. Car top inspection station with UP and DOWN
test switches, emergency stop, light outlet
8. Automatic homing to the lowest fl oor (optional)
9. Slack rope safety.
10. Anti-creep device.
11. Overspeed governor (may not be
required) – consult AHJ
12. Dual direction leveling.
• Upper and lower terminal limit.
• Pump run timer.
• Pit clearance device (where required)
• Automatic battery powered and manual
emergency lowering control devices.
• Minimum pressure switch.
• Maintenance stop blocks.
(specify
option:) Fire Fighters Service (available).
(specify
option:) Hall lanterns with chime.
(specify
option:) Recessed telephone cabinet
(brushed stainless steel or brushed brass).
(specify
option:) Buffer springs (requires 24" pit).
1.4 QUALITY ASSURANCE
A. Manufacturer: Provide elevator manufactured by
a fi rm with a minimum of 10 years experience in
fabrication of elevators equivalent to those specifi ed.
B. All designs, clearances, workmanship and
material, unless specifi cally accepted, shall be in
accordance with all codes having legal jurisdiction.
C. All load ratings and safety factors shall meet
or exceed those specifi ed by all governing
agencies with jurisdiction and shall be
certifi ed by a professional engineer.
D. Elevator shall be subject to applicable state, local
and city approval prior to installation and subject
to inspection after installation. Determination
of and adherence to these regulations is the
responsibility of the elevator contractor.
E. Welders certifi ed in accordance with requirements of
AWS D1.1 or CWB shall perform all welding of all parts.
F. Substitutions: No substitutions permitted.
1.5 WARRANTY
A. Warranty: Manufacturer shall warrant component
parts of the Orion elevator for a period of 36 months
from shipping date. This warranty only applies to
products installed and maintained by a Savaria
Authorized Dealer in conformance with all applicable
local and national codes. The warranty is void if
regular inspection and maintenance of product
is not being carried out by an Authorized Savaria
Dealer in accordance with the recommendations
contained in the Owner's Manual. It is the Owner's
responsibility to keep records of all such service.
Part No. 000682 15-m10-2015