Page 1
Telecab Residential Elevator OWNER’S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000627 09-m03-2010...
Page 2
IMPORTANT Ensure that only an authorized Savaria Dealer installs and services the Telecab Residential Elevator. Under no circumstances is anyone other than a dealer with Savaria training and authorization to install, adjust, service or modify any mechanical or electrical device on this equipment. Failure to follow this warning can result in safety system compromises or defeat;...
TO ENSURE SAFE OPERATION To ensure safe operation of this equipment, pay careful attention to the important notes below. • Read this manual carefully before using the Telecab Residential Elevator. • To prevent accidents, adhere strictly to the instructions and keep clear of moving parts at all times.
1. DESCRIPTION Figure 1 shows the exterior components of the Telecab. Figure 1 Description Description Tower Hall station (call/send) Floor plug Car operating panel (COP) Emergency telephone Door handles Electromechanical door lock Door latch Non-skid platform Cab door Safety underpan Part No.
(762 mm x 1168 mm x 1981 mm) Door size H78” x W30” steel with Plexiglas insert Minimum overhead 90” (2286 mm) at top landing clearance Minimum floor cutout 34” x 59” (864 mm x 1499 mm) Telecab Owner’s Manual Part No. 000627, 09-m03-2010...
Page 7
Custom cab size (without ABS vacuum formed plastic finish) Optional equipment Custom color Horizontal plastic panel on hinged side Wired remote control in cab Hydraulic door closer Automatic door operator (without ABS vacuum formed plastic finish) Part No. 000627, 09-m03-2010 Telecab Owner’s Manual...
2 Apply constant pressure on the appropriate up/down button to move the Telecab in the desired direction. Note that the Telecab will not move if the door is open or if an object activates the underpan sensor or the floor plug sensor.
2 Apply constant pressure on the appropriate up/down button to move the Telecab in the desired direction. Note that the Telecab will not move if the door is open or if an object activates the underpan sensor or the floor plug sensor.
Door Lock and Open Door Sensor The electric strike keeps the door locked when the Telecab is operating or not at a landing. The door open sensor prevents the Telecab from moving when the door is open. Emergency Door Opening The door can be opened manually from the interior or exterior of the Telecab using a 1/4”...
Pressing the red Emergency Stop button during travel will stop the elevator immediately and activate the alarm. The Emergency Stop overrides the landing stations (hall calls). Pull the Emergency Stop out to return the elevator to normal operation. Telecab Owner’s Manual Part No. 000627, 09-m03-2010...
Manual Lowering and Battery Lowering System If a power failure occurs, a battery lowering system will bring the Telecab to the bottom level. If the battery fails while operating, there is also a remote manual lowering device that you can use to lower the Telecab to the bottom level.
Qualified Technician. Contact your Authorized Dealer Maintenance Schedule Verification by owner Frequency Verify general operation of the Telecab Every 2 months Verify operation of the safety devices: • Underpan sensors (safety switches) • Floor plug sensors (safety switches) Every 2 months •...
Check to see if the Emergency Stop is pushed in; it should be pulled out for normal operation. Telecab does not move. If the Telecab is at the bottom landing, check the floor plug switches as described above. If the Telecab is at the top landing, check the underpan sensor as described above.