General Specifications - Savaria Eclipse Owner's Manual

Residential elevator
Hide thumbs Also See for Eclipse:
Table of Contents

Advertisement

1.

GENERAL SPECIFICATIONS

Load capacity
Rated speed
Power supply
(circuit supplied by others)
Lighting supply
(circuit supplied by others)
Drive system
Temperature operating
range
Cab sizes
Cab panel and finish
Maximum travel
Control system
Levels and openings
Pit depth requirement
Minimum overhead
clearance
Hall station and control
panel finish
Standard features
ECLIPSE RESIDENTIAL ELEVATOR
750 lbs. (340 kg), 950 lbs. (431 kg), 1000 lbs. (454 kg)
40 feet per minute (0.20 mps) (standard)
208 volt - 230 volt, single phase, 60 Hz, 20 amps, North America
220 volt - single phase, 50 Hz, International
120 volt, 60 cycle, 15 amps
Automatic 2HP-geared motor roller chain variable frequency drive, complete
with counterweight
- 10 °C to + 40 °C / 14 °F to 104 °F
W36" x L48" x H80" (914 mm x 1219 mm x 2032 mm), Type 1, 2, 3, 4, 5
W36" x L54" x H80" (914 mm x 1371 mm x 2032 mm), Type 1, 2, 3, 4, 5
W36" x L60" xH80" (914 mm x 1524 mm x 2032 mm), Type 1, 2, 3, 4, 5
W40" x L54" x H80" (1067 mm x 1371 mm x 2032 mm), Type 1, 2, 3, 4, 5
Solid melamine or MDF panels - standard; unfinished veneer panels - optional;
finished recessed veneer panels - optional; solid hardwood raised panels -
optional
50 feet (12.24 m), 60 feet (18.29 m) available where code is not applicable
Relay logic controller complete with diagnostic LEDs
Up to 4 stops / up to 2 cab openings
6" (152 mm), 11" (279 mm) minimum with buffer springs
96" (2438 mm) for standard 80" cab, 114" (2896 mm) for 96" cab
Clear bronze anodized aluminum (standard), or stainless steel (optional), or
brass (optional)
Rectangular (standard) or oval (optional) hall stations, keyless (standard) or
keyed (optional)
Automatic cab on/off lighting
Recessed gate pocket
Digital display in cab operating panel
Clear or bronze anodized aluminum cab entrance trim and handrail
Data plates, capacity tags
Proximity floor selection, stopping and two-way levelling
Home landing feature
Presentation drawings
Modular rail sections
Unfinished plywood sub-floor
White ceiling with four incandescent pot lights
4 of 14