Savaria Infinity Planning Manual

Residential elevators
Hide thumbs Also See for Infinity:
Table of Contents

Advertisement

Quick Links

Infinity &
Infinity HD
RESIDENTIAL ELEVATORS
Planning Guide
Applicable Codes:
ASME A17.1/CSA-B44
Safety Code for Elevators and Escalators
Section 5.3 – Private Residential Elevators
Part No. 000783
24-m09-2015
 2015 Savaria Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Savaria Infinity

  • Page 1 Infinity & Infinity HD RESIDENTIAL ELEVATORS Planning Guide Applicable Codes: ASME A17.1/CSA-B44 Safety Code for Elevators and Escalators Section 5.3 – Private Residential Elevators Part No. 000783 24-m09-2015  2015 Savaria Corporation...
  • Page 2 Copyright 2015 Savaria Corporation All Rights Reserved Printed in Canada...
  • Page 3 3 Determine the site installation parameters. 4 Determine the cab type and hoistway size requirements. NOTE: If the Infinity/Infinity HD also has Auto Slim Doors, do not refer to the tables on pages 6 and 7; refer instead to Appendix A.
  • Page 4: Product Description

    (COP) INFINITY IN HOISTWAY Meets Americans with Disabilities Act (ADA) requirements The Infinity and Infinity HD meet the requirements of the ADA Accessibility Guidelines as a means to provide public building access. Design assistance With over 30 years of experience. Savaria has the expertise to provide solutions to practically every design challenge you face.
  • Page 5: Infinity/Infinity Hd Specifications

    Infinity/Infinity HD specifications Specification type Specification data Load capacity Infinity: 750 lb (341 kg), 950 lb (431 kg) or 1000 lb (454 kg) Infinity HD: 1400 lb (635 kg) Rated speed 36 ft/min (0.18 m/s) nominal Maximum travel 50 ft (15.24 m) – confirm with local code...
  • Page 6: Infinity/Infinity Hd Cab Types

    Finished hoistway dimensions must include the drywall. Determine the fire rating of the hoistway, the type and layers of sheet rock and build only off the final installation (shop) drawings specific to your project. Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 7: Machine Room Options

    The machine room must be free of any pipes, wiring and obstructions not related to the operation of the lift. Provide a 4 inch conduit from the lift shaft to the remote machine room. Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 8: Machine Room Dimensions

    Machine room dimensions Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 9: Controller Tank Specifications

    • Hydraulic hose connection port on both sides of the tank • Built-in handles on both sides of the tank • Isolation mounting of pump motor valve assembly minimizes operating issues Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 10: Elevation View - Infinity

    IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawing; refer to Appendix A instead. Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 11: Elevation View - Infinity Hd

    Elevation view – Infinity HD Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 12 IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawings; refer to Appendix A instead. Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 13 IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawings; refer to Appendix A instead. Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 14 IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawings; refer to Appendix A instead. Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 15 IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawings; refer to Appendix A instead. Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 16 IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawings; refer to Appendix A instead. Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 17 IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawings; refer to Appendix A instead. Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 18 IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawings; refer to Appendix A instead. Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 19 IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawings; refer to Appendix A instead. Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 20 IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawings; refer to Appendix A instead. Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 21 IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawings; refer to Appendix A instead. Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 22 IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawings; refer to Appendix A instead. Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 23 IMPORTANT : Always refer to your plan drawings for dimensions specific to your site. For Infinity with Auto Slim Doors, DO NOT use the above drawings; refer to Appendix A instead. Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 24: Plan View - Infinity Hd 48" X 60" Type 1 Left-Hand

    Plan view – Infinity HD 48” x 60” type 1 left-hand Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 25: Plan View - Infinity Hd 48" X 60" Type 1 Right-Hand

    Plan view – Infinity HD 48” x 60” type 1 right-hand Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 26 Plan view – Infinity HD 48” x 60” type 2 Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 27 Plan view – Infinity HD 48” x 60” type 3 Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 28 Plan view – Infinity HD 48” x 60” type 4 Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 29: Plan View - Infinity Hd 48" X 60" Type 5 (Left-Hand Gate Stack/Door Swing)

    Plan view – Infinity HD 48” x 60” type 5 (left-hand gate stack/door swing) Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 30: Plan View - Infinity Hd 48" X 60" Type 5 (Right-Hand Gate Stack/Door Swing)

    Plan view – Infinity HD 48” x 60” type 5 (right-hand gate stack/door swing) Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 31: Door And Gate Specifications

    Door and gate specifications For door and gate specifications, go to our website www.savaria.com, select the “architects and builders” tab at the top of the page and then select “Doors and Gates” from the menu on the left-hand side of the page.
  • Page 32 Loads on building and rail dimensions Rail bracket dimensions (Infinity HD) Rail bracket dimensions (Infinity) Rails Support wall orientation Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 33: Pit Details

    #5 reinforcing steel (grade 60) must be placed at the bottom of the slab in two traverse directions and at a spacing of 12” (305 mm). • Hoistway pit floor to support a load (including impact) of 5.6 kips (5600 lb/24.9 kN) for Infinity or 8.22 kips (8220 lb/36.6 kN) for Infinity HD.
  • Page 34: Masonry Construction - Sectional View

    Masonry construction – sectional view Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 35: Masonry Construction - Plan View

    Masonry construction – plan view Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 36 Wood construction – sectional view For Reference Only Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 37: Wood Construction - Plan View

    Wood construction – plan view Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 38 Suggested wall configuration for wood construction (sheet 1) Refer to previous section “Loads on building” for rail forces R1, R2, R3. Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 39: Suggested Wall Configuration For Wood Construction (Sheet 2)

    Suggested wall configuration for wood construction (sheet 2) Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 40: Rail Support Wall Specifications

    See the lift installation (shop) drawings for service loads (including dynamic effects) which are: • Horizontal load parallel to the wall: 194 lbf (0.86 kN) for Infinity; 251 lbf (1.12 kN) for Infinity HD • Horizontal load perpendicular to the wall: 304 lbf (1.35 kN) for Infinity; 422 lbf (1.88 kN) for Infinity HD Wood: SPF NO 1/2 Mix...
  • Page 41: Provisions By Others

    3-pole breaker for battery feed required, in compliance with electrical code, located on the wall on the lock jamb side of the machine room door. Contact your Savaria dealer or refer to one of the tables on the next page for OEM part numbers.
  • Page 42 CFN 211 Required Type “D” Fuse (Buss type “T” or equal) 1@15 amp 1@15 amp 1@15 amp For Infinity HD (5 HP pump unit) Disconnect Switch Types & Accessories Cutler Hammer Federal Pioneer Siemens 1 Phase 5 H.P. Pump Unit...
  • Page 43: Cop Dimensions

    COP dimensions Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 44: Hall Call Dimensions

    Hall call dimensions Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 45: Appendix A Infinity With Auto Slim Doors

    Appendix A Infinity with Auto Slim Doors This appendix provides elevation and plan view drawings for the various Infinity cab types with Auto Slim Doors. Drawings for the auto slim doors entrance assembly are provided on the next two pages.
  • Page 46: Auto Slim Doors Entrance Assembly, Co = 2100

    Auto slim doors entrance assembly, CO = 2100 Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 47: Elevation View - Infinity Type 1L With Auto Slim Doors

    Elevation view – Infinity type 1L with auto slim doors Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 48: Plan View - Infinity Type 1L With Auto Slim Doors

    Plan view – Infinity type 1L with auto slim doors Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 49: Elevation View - Infinity Type 1R With Auto Slim Doors

    Elevation view – Infinity type 1R with auto slim doors Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 50: Plan View - Infinity Type 1R With Auto Slim Doors

    Plan view – Infinity type 1R with auto slim doors Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 51: Elevation View - Infinity Type 2 With Auto Slim Doors

    Elevation view – Infinity type 2 with auto slim doors Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 52: Plan View - Infinity Type 2 With Auto Slim Doors

    Plan view – Infinity type 2 with auto slim doors Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 53: Elevation View - Infinity Type 3 With Auto Slim Doors

    Elevation view – Infinity type 3 with auto slim doors Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 54: Plan View - Infinity Type 3 With Auto Slim Doors

    Plan view – Infinity type 3 with auto slim doors Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 55: Elevation View - Infinity Type 4 With Auto Slim Doors

    Elevation view – Infinity type 4 with auto slim doors Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 56: Plan View - Infinity Type 4 With Auto Slim Doors

    Plan view – Infinity type 4 with auto slim doors Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 57: Elevation View - Infinity Type 5 With Auto Slim Doors

    Elevation view – Infinity type 5 with auto slim doors Part No. 000783, 24-m09-2015 Infinity and Infinity HD Planning Guide...
  • Page 58: Plan View - Infinity Type 5 With Auto Slim Doors

    Plan view – Infinity type 5 with auto slim doors Infinity and Infinity HD Planning Guide Part No. 000783, 24-m09-2015...
  • Page 60 2 Walker Drive Brampton, ON Canada L6T 5E1 Phone: 905-791-5555 Fax: 905-791-2222 Sales: 800-661-5112 www.savaria.com...

This manual is also suitable for:

Infinity hd

Table of Contents