LOADS ON BUILDING AND PIT LOADING

Seismic zones 0 and 1
720 lbf
260 lbf
Rail reactions do not include safety factors. Applicable safety factors must be considered in hoistway design.
Rail Bracket Dimensions
Page 18 of 27
Orion Planning Guide
Seismic zone 2
Seismic zone 3 or greater
2400 lbf
1200 lbf
300 lbf
400 lbf
Rails
Support Wall Orientation
R3- Condition I: when fully loaded car hits buffer (bumper)
R4 - Condition II: when safeties engage on rails with 110%
loaded car at governor tripping speed
R5 - Condition III: normal running with 1.2 times impact for
starting and stopping jerks
Part No. 000682 15-m10-2015