ORION 48” X 54” TYPE 1 WITH 2 SPEED DOORS ORION 48” X 54” TYPE 2 WITH 2 SPEED DOORS ORION 48” X 54” TYPE 3 (4) WITH 2 SPEED DOORS ORION 42” X 60” TYPE 1 WITH 2 SPEED DOORS ORION 42”...
Lift confi gurations and dimensions are in accordance with our interpretation of the standards set forth by AASME A17.1 - 2004 Section 5.2 and CAN/CSA B44 - 04. Please consult Savaria or the authorized Savaria dealer in your area for more specifi c information pertaining to your project, including any discrepancy between referenced standards and those of any local codes or laws (AHJ).
Panel Orion in Hoistway Meets (ADA) Americans with Disabilities Act Requirements The Orion meets the requirements of the ADA Accessibility Guidelines as a means to provide public building access. Design Assistance With over 30 years of experience. Savaria has the expertise to provide solutions to practically every design challenge you face.
Raised plastic laminated panels in a choice of 7 colors Recessed stainless steel or brass telephone cabinet The Orion meets the requirements of multiple ASME A17 code years for a LU/LA Elevator. Contact sales for further information. Page 5 of 27 Orion Planning Guide Part No.
Finished hoistway dimensions must include the drywall. Determine the fi re rating of the hoistway, the type and layers of sheet rock and build only off the fi nal shop drawings specifi c to your project. Page 6 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
Machine room is required to be free of all pipes, wiring and obstructions not related to the operation of the o elevator. Provide a 4 inch conduit from the lift shaft to the remote machine room. Page 7 of 27 Orion Planning Guide Part No. 000682 15-m10-2015...
Built in handles on either side of the tank • Isolation mounting of pump motor valve assembly minimizes operating noise " 0 " 1 " 9 " 0 " 5 PLC Controller Tank Page 10 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
ORION 48” X 54” TYPE 1 WITH 2 SPEED DOORS Finished hoistway dimensions must include the drywall (where applicable). Type 1 Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
ORION 48” X 54” TYPE 2 WITH 2 SPEED DOORS Finished hoistway dimensions must include the drywall (where applicable). Type 2 Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
ORION 51” X 51” TYPE 3 (4) WITH 2 SPEED DOORS Type 3 or 4 Finished hoistway dimensions must include the drywall (where applicable). Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
ORION 42” X 60” TYPE 1 WITH 2 SPEED DOORS Type 1 Finished hoistway dimensions must include the drywall (where applicable). Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
ORION 42” X 60” TYPE 2 WITH 2 SPEED DOORS Type 2 Finished hoistway dimensions must include the drywall (where applicable). Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
ORION 48” X 54” TYPE 1 WITH SWING DOORS Type 1 Finished hoistway dimensions must include the drywall (where applicable). Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
ORION 48” X 54” TYPE 2 WITH SWING DOORS Type 2 Finished hoistway dimensions must include the drywall (where applicable). Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
R4 - Condition II: when safeties engage on rails with 110% loaded car at governor tripping speed R5 - Condition III: normal running with 1.2 times impact for starting and stopping jerks Page 18 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
ENTRANCE MOUNTING DETAILS FOR 2 SPEED DOORS WITH DRYWALL CONSTRUCTION Contractor please note: Grouting at the sill may be required after the door frames are set. Page 20 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
ENTRANCE MOUNTING DETAILS FOR 2 SPEED DOORS WITH MASONRY CONSTRUCTION Contractor please note: Grouting at the sill may be required after the door frames are set. Page 22 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
40.25” x 25.4 = 1022.35 mm Door Frame Elevation Notes: See hoistway requirements for the location of the door centerline. Door panels and frame are primed for painting. Rails ands Sling in Hoistway Page 23 of 27 Orion Planning Guide Part No. 000682 15-m10-2015...
PIT AND OVERHEAD CLEARANCE DETAILS 14” Pit Depth A minimum pit depth of 14” is required. Page 24 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
Power supply with a lockable fused disconnect and auxiliary contact to brake the battery feed, or circuit breakers with a 3-pole breaker for battery feed required in compliance with electrical code (contact your Savaria dealer or refer to the table below for OEM part numbers). Disconnect Switch Types & Accessories...
A. Warranty: Manufacturer shall warrant component brushed brass panel with illuminated button and parts of the Orion elevator for a period of 36 months (specify option:) key lock provided at each landing. from shipping date. This warranty only applies to products installed and maintained by a Savaria 3.
Page 27
Phone (905) 791-5555 3.3 INSTALLATION Fax (905) 791-2222 Web site: http://www.savaria.com A. The Orion elevator shall be installed in accordance with manufacturer’s instructions 2.2 MATERIAL and as specifi ed and approved by architect. • Guide Rail: Dual 8 lbs./ft. machined 3.4 DEMONSTRATION...