Savaria ORION Planning Manual

Limited use/limited application elevator
Hide thumbs Also See for ORION:

Advertisement

ORION
TM
LIMITED USE / LIMITED APPLICATION ELEVATOR
Planning Guide
Limited Use / Limited Application Elevator
Applicable Codes:
ASME A17.1, Section 5.2
CAN/CSA B44, Section 5.2
Part No. 000682
15-m10-2015
© 2015 Savaria Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Savaria ORION

  • Page 1 ORION LIMITED USE / LIMITED APPLICATION ELEVATOR Planning Guide Limited Use / Limited Application Elevator Applicable Codes: ASME A17.1, Section 5.2 CAN/CSA B44, Section 5.2 Part No. 000682 15-m10-2015 © 2015 Savaria Corporation...
  • Page 2: Table Of Contents

    ORION 48” X 54” TYPE 1 WITH 2 SPEED DOORS ORION 48” X 54” TYPE 2 WITH 2 SPEED DOORS ORION 48” X 54” TYPE 3 (4) WITH 2 SPEED DOORS ORION 42” X 60” TYPE 1 WITH 2 SPEED DOORS ORION 42”...
  • Page 3: General

    Lift confi gurations and dimensions are in accordance with our interpretation of the standards set forth by AASME A17.1 - 2004 Section 5.2 and CAN/CSA B44 - 04. Please consult Savaria or the authorized Savaria dealer in your area for more specifi c information pertaining to your project, including any discrepancy between referenced standards and those of any local codes or laws (AHJ).
  • Page 4: Product Description

    Panel Orion in Hoistway Meets (ADA) Americans with Disabilities Act Requirements The Orion meets the requirements of the ADA Accessibility Guidelines as a means to provide public building access. Design Assistance With over 30 years of experience. Savaria has the expertise to provide solutions to practically every design challenge you face.
  • Page 5: Orion Lu/La Elevator Specifications

    Raised plastic laminated panels in a choice of 7 colors Recessed stainless steel or brass telephone cabinet The Orion meets the requirements of multiple ASME A17 code years for a LU/LA Elevator. Contact sales for further information. Page 5 of 27 Orion Planning Guide Part No.
  • Page 6: Cab Type Selection Sheet

    Finished hoistway dimensions must include the drywall. Determine the fi re rating of the hoistway, the type and layers of sheet rock and build only off the fi nal shop drawings specifi c to your project. Page 6 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
  • Page 7: Machine Room Options

    Machine room is required to be free of all pipes, wiring and obstructions not related to the operation of the o elevator. Provide a 4 inch conduit from the lift shaft to the remote machine room. Page 7 of 27 Orion Planning Guide Part No. 000682 15-m10-2015...
  • Page 8: Machine Room Dimensions

    MACHINE ROOM DIMENSIONS Page 8 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
  • Page 9: Hoistway And Pit Electrical Notes

    fi nished fl oor light switch mounted directly above. 9” Clear Distance (from inside fi nished surface of hoistway to edge of electrical box). 9” Page 9 of 27 Orion Planning Guide Part No. 000682 15-m10-2015...
  • Page 10: Controller Tank Specifications

    Built in handles on either side of the tank • Isolation mounting of pump motor valve assembly minimizes operating noise " 0 " 1 " 9 " 0 " 5 PLC Controller Tank Page 10 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
  • Page 11: Orion 48" X 54" Type 1 With 2 Speed Doors

    ORION 48” X 54” TYPE 1 WITH 2 SPEED DOORS Finished hoistway dimensions must include the drywall (where applicable). Type 1 Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
  • Page 12: Orion 48" X 54" Type 2 With 2 Speed Doors

    ORION 48” X 54” TYPE 2 WITH 2 SPEED DOORS Finished hoistway dimensions must include the drywall (where applicable). Type 2 Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
  • Page 13: Orion 48" X 54" Type 3 (4) With 2 Speed Doors

    ORION 51” X 51” TYPE 3 (4) WITH 2 SPEED DOORS Type 3 or 4 Finished hoistway dimensions must include the drywall (where applicable). Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
  • Page 14: Orion 42" X 60" Type 1 With 2 Speed Doors

    ORION 42” X 60” TYPE 1 WITH 2 SPEED DOORS Type 1 Finished hoistway dimensions must include the drywall (where applicable). Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
  • Page 15: Orion 42" X 60" Type 2 With 2 Speed Doors

    ORION 42” X 60” TYPE 2 WITH 2 SPEED DOORS Type 2 Finished hoistway dimensions must include the drywall (where applicable). Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
  • Page 16: Orion 48" X 54" Type 1 With Swing Doors

    ORION 48” X 54” TYPE 1 WITH SWING DOORS Type 1 Finished hoistway dimensions must include the drywall (where applicable). Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
  • Page 17: Orion 48" X 54" Type 2 With Swing Doors

    ORION 48” X 54” TYPE 2 WITH SWING DOORS Type 2 Finished hoistway dimensions must include the drywall (where applicable). Determine the fi re rating of the hoistway, the type and layers of sheet rock. Build only from shop drawings specifi c to your project.
  • Page 18: Loads On Building And Pit Loading

    R4 - Condition II: when safeties engage on rails with 110% loaded car at governor tripping speed R5 - Condition III: normal running with 1.2 times impact for starting and stopping jerks Page 18 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
  • Page 19: Entrance Mounting Details For 2 Speed Doors With Drywall Construction

    ENTRANCE MOUNTING DETAILS FOR 2 SPEED DOORS WITH DRYWALL CONSTRUCTION Page 19 of 27 Orion Planning Guide Part No. 000682 15-m10-2015...
  • Page 20: Entrance Mounting Details For 2 Speed Doors With Drywall Construction

    ENTRANCE MOUNTING DETAILS FOR 2 SPEED DOORS WITH DRYWALL CONSTRUCTION Contractor please note: Grouting at the sill may be required after the door frames are set. Page 20 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
  • Page 21: Entrance Mounting Details For 2 Speed Doors With Masonry Construction

    ENTRANCE MOUNTING DETAILS FOR 2 SPEED DOORS WITH MASONRY CONSTRUCTION Page 21 of 27 Orion Planning Guide Part No. 000682 15-m10-2015...
  • Page 22: Entrance Mounting Details For 2 Speed Doors With Masonry Construction

    ENTRANCE MOUNTING DETAILS FOR 2 SPEED DOORS WITH MASONRY CONSTRUCTION Contractor please note: Grouting at the sill may be required after the door frames are set. Page 22 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
  • Page 23: Speed Automatic Door And Guide Rail Information

    40.25” x 25.4 = 1022.35 mm Door Frame Elevation Notes: See hoistway requirements for the location of the door centerline. Door panels and frame are primed for painting. Rails ands Sling in Hoistway Page 23 of 27 Orion Planning Guide Part No. 000682 15-m10-2015...
  • Page 24: Pit And Overhead Clearance Details

    PIT AND OVERHEAD CLEARANCE DETAILS 14” Pit Depth A minimum pit depth of 14” is required. Page 24 of 27 Part No. 000682 15-m10-2015 Orion Planning Guide...
  • Page 25: Orion Standard Notes

    Power supply with a lockable fused disconnect and auxiliary contact to brake the battery feed, or circuit breakers with a 3-pole breaker for battery feed required in compliance with electrical code (contact your Savaria dealer or refer to the table below for OEM part numbers). Disconnect Switch Types & Accessories...
  • Page 26: Specifications For Part 5.3 Compliance

    A. Warranty: Manufacturer shall warrant component brushed brass panel with illuminated button and parts of the Orion elevator for a period of 36 months (specify option:) key lock provided at each landing. from shipping date. This warranty only applies to products installed and maintained by a Savaria 3.
  • Page 27 Phone (905) 791-5555 3.3 INSTALLATION Fax (905) 791-2222 Web site: http://www.savaria.com A. The Orion elevator shall be installed in accordance with manufacturer’s instructions 2.2 MATERIAL and as specifi ed and approved by architect. • Guide Rail: Dual 8 lbs./ft. machined 3.4 DEMONSTRATION...
  • Page 28 2 Walker Drive Brampton, ON Canada L6T 5E1 Phone: 905-791-5555 Fax: 905-791-2222 Sales: 800-661-5112 www.savaria.com...

Table of Contents