Load capacity
Maximum travel
Travel speed
Tower
Control system
Levels serviced
Platform
Power supply
(circuit supplied by others)
Lighting supply
(circuit supplied by others)
Motor/pump
Electrical
Drive system
Temperature operating
range
Cab access
Cab dimensions
Door size
Minimum overhead
clearance
Minimum floor cutout
Telecab Owner's Manual
500 lbs. (227 kg)
23 ft (7.0 m) maximum
25 ft/min (0.13 m/s) standard
Modular 8 ft (2.4 m) guide rail assembly
with roller guide shoes
115 VAC relay logic operation
115 VAC up direction and 12 VDC down direction
2 levels (3 optional)
Non-skid platform
110 VAC, 20 A, 60 Hz, single phase
120 volt, 60 Hz, single phase
110 VAC, 1.5 HP screw type
Automatic battery recharging system (115 VAC)
Low voltage controls
2:1 roller chain hydraulic
–10 °C to +40 °C (14 °F to 104 °F)
Front access only (standard)
Left or right access (optional); with optional 2-door
access
W30" x L46" x H78"
(762 mm x 1168 mm x 1981 mm)
H78" x W30" steel with Plexiglas insert
90" (2286 mm) at top landing
34" x 59" (864 mm x 1499 mm)