Savaria ORION Planning Manual page 27

Limited use/limited application elevator
Hide thumbs Also See for ORION:
Table of Contents

Advertisement

PART 2 PRODUCT
2.1 MANUFACTURER
Provide the Orion Commercial LU/LA
Elevator manufactured by Savaria.
Toll Free Number (800) 661-5112
Phone (905) 791-5555
Fax (905) 791-2222
Web site: http://www.savaria.com
2.2 MATERIAL
• Guide Rail: Dual 8 lbs./ft. machined
steel T-rail system.
• Wire Rope: Two 3/8" diameter 7 x 19 ga. IWRC
aircraft cables with rope wedge sockets.
• Sling: Structural and formed steel
plates with guide shoes.
• Platform Floor: Unfi nished plywood fl ooring.
2.3 FINISHES
A. Components shall be prepared with
1) pre-treatment,
2) alkaline detergent wash,
3) clear water rinse,
4) iron phosphate coating,
5) clear water rinse and fi nished with electrostatically
applied and baked thermostatic powder coat
fi nish. Standard color is architectural white.
2.4 ELECTRICAL SYSTEMS
A. The electrical contractors shall provide:
1. 208V three phase 30 AMP 60 Hz or 230 V single
phase 40 AMP 60 Hz source in the machine area
with manually operated fused line disconnect.
2. 115 VAC, single phase, 15 amp, 60 Hz,
single phase power source with manually
operated fused line disconnect for car lighting
and a light outlet inside the hoistway.
3. Telephone circuit in the machine area.
PART 3 EXECUTION
3.1 ACCEPTABLE INSTALLERS
A. Installers shall be experienced in performing
work of this section who have specialized in work
comparable to that required for this project.
B. Installers shall be certifi ed and
trained by the manufacturer.
Part No. 000682 15-m10-2015
3.2 EXAMINATION
A. Use fi eld dimensions and approved manufacturer's
shop drawings to examine substrates, supports
and other conditions under which this work is
to be performed. Do not proceed with work until
unsatisfactory conditions are corrected.
3.3 INSTALLATION
A. The Orion elevator shall be installed in
accordance with manufacturer's instructions
and as specifi ed and approved by architect.
3.4 DEMONSTRATION
A. The elevator contractor shall make a fi nal check of
the elevator's operation with the Owner or Owner's
representative present prior to turning the elevator over
for use. The elevator contractor shall determine that
operating and safety devices are functioning properly.
END OF SECTION
Intent of specifi cation is to broadly outline equipment
required but does not cover details of design and
construction. Dimensions and specifi cations are subject
to constant change and continually evolving codes and
product applications. For additional technical information,
contact Savaria at (800) 661-5112 or www.savaria.com.
Page 27 of 27