1. Loosen the three screws [A] [B].
2. Turn the eccentric bushing [C], if the back edge of the master comes close to
the non-operation side.
NOTE: 1) As a rough guide, if the edges moved to the non-operation side by
1.0 mm, turn the eccentric bushing [C] counterclockwise one
graduation.
2) Please check the machine after adjusting, because the effect of
moving the bushing by one graduation differs for each machine. To
do this, print about 1000 sheets and compare the 10
th
1000
3. Tighten the screw [B].
4. Shift the drum position plate [D] in the paper table direction (to the right) and
tighten the two screws [A].
SM
sheet.
3-73
DRUM SECTION
th
sheet with the
C262/C265