5. Insert a 0.08-mm gap gauge between the doctor roller and the ink roller. Then,
make sure that a 0.1-mm gauge cannot pass through the gap.
NOTE: Check the gap at the left, center, and right.
6. If the gap is not correct, loosen the screws [B] on both sides and adjust the gap
by turning the eccentric bushings [C] at each side.
SM
[B]
3-69
DRUM SECTION
[C]
C262R068.WMF