Danfoss PVG 100 Technical Information page 31

Proportional valve group
Hide thumbs Also See for PVG 100:
Table of Contents

Advertisement

Technical Information
PVG 100 Proportional Valve Group
Technical characteristics
©
Danfoss | May 2018
Oil flow as a function of spool travel for spools A to F - 15 bar [218 psi]
Q
Q
A/B
A/B
US
P
gal/min
l/min
l/min
60
225
200
50
175
40
150
125
30
100
20
75
50
10
25
0
0
0
1
2
3
0
0.04
0.08
0.12
5
7
9
73
100
130
0.50
0.55
0.60
Set pressure difference between pump pressure and LS signal = 15 bar [218 psi] measured at the P-port
of the valve.
PVLP, shock and suction valve
A/B
F
E
D
C
B
A
a
PVM
mm
4
5
6
7
a
0.16
0.20
0.24
0.28
in
p
11
13
15
bar
p
psi
160
190
218
U
s
U
0.65
0.70
0.75
DC
157-690.11
PVM
PVH
PVH
PVE
520L0720 | BC00000039en-US0502 | 31