Modules And Code Numbers; Pvpf (Open Center) Inlet Modules - For Pumps With Fixed Displacement; Pvpf Accessories For Pump Side Modules - Danfoss PVG 100 Technical Information

Proportional valve group
Hide thumbs Also See for PVG 100:
Table of Contents

Advertisement

Technical Information
PVG 100 Proportional Valve Group

Modules and code numbers

PVPF (Open Center) Inlet Modules - for Pumps with Fixed Displacement

Symbol
Refer to PVPE and Dummy
Spool in PVPF Acessories
T0
P
gage
P
P
P
T P
P
P
Refer to PVPE and Dummy
Spool in PVPF Acessories
T0
P
gage
P
P
P
T P
P
P
Refer to PVPP in PVP Accessory Section
*
PVPD (dummy spool)/PVPE/PVPH should be specified with any PVPF module. **PVPE/PVPH will electrically or hydraulically unload pump flow to tank
for a low pressure standby (refer to

PVPF Accessories for Pump Side Modules

Symbol
PVPE
T0
P
gage
P
P
P
T P
P
P
Ls
T0
P
gage
P
P
P
*
Connection for external pilot pressure: available with G1/4 thread only. Pilot source should be independent of LS pressure (LS pressure may not be
enough to pilot PVPH).
©
Danfoss | May 2018
Description
Open center pump side module for pumps with fixed
displacement.
LS
Max pump flow 250 l/min [66 US gal/min].
With pilot supply for PVE actuation.
With pilot gauge port.
Open center pump side module for pumps with fixed
displacement.
Max pump flow 250 l/min [66 US gal/min].
LS
LS
T0
With pilot supply for PVH/PVHC actuation.
P301 051
With pilot gauge port.
Open center pump side module for pumps with fixed
displacement.
LS
Max pump flow 250 l/min [66 US gal/min].
With pilot supply for PVE actuation.
Accumulator port and facility for pilot shut-off valve
(PVPP).
Open center pump side module for pumps with fixed
displacement.
LS
LS
T0
Max pump flow 250 l/min [66 US gal/min].
With pilot supply for PVH/PVHC actuation.
P301 052
Accumulator port and facility for pilot shut-off valve
(PVPP).
Technical characteristics
on page 28).
Description
Dummy Spool
PVPE
LS
Electrically actuated normally open, unloading valve
If PVPE or PVPH is not required the "Dummy Spool" must
be specified
LS
LS
T0
P301 053
PVPH
Hydraulically actuated unloading valve
If PVPE or PVPH is not required the "Dummy Spool" must be
specified.
P301 797
BSP port
SAE Port
G1
1 5∕16-12
12 bar
161B5110
161B5510
*
spring
20 bar
161B5112
161B5512
*
spring
12 bar
11013065
11013066
*
spring
20 bar
11013067
11013068
*
spring
12 bar
161B5140
161B5540
*
spring
20 bar
161B5142
161B5542
*
spring
12 bar
11013071
11013072
*
spring
20 bar
11013073
11013074
*
spring
*
Spring for pressure matching spool -
PVPF only.
Code Number
155G5041
12 V
155G5052
24 V
155G5054
*
155G5061
520L0720 | BC00000039en-US0502 | 39

Hide quick links:

Advertisement

Table of Contents
loading