Please Read This Notice
Successful application of this module requires a reasonable working knowledge of the Rockwell
Automation ControlLogix hardware, the MVI56-CAS Module and the application in which the
combination is to be used. For this reason, it is important that those responsible for implementation
satisfy themselves that the combination will meet the needs of the application without exposing
personnel or equipment to unsafe or inappropriate working conditions.
This manual is provided to assist the user. Every attempt has been made to ensure that the
information provided is accurate and a true reflection of the product's installation requirements. In
order to ensure a complete understanding of the operation of the product, the user should read all
applicable Rockwell Automation documentation on the operation of the Rockwell Automation
hardware.
Under no conditions will ProSoft Technology be responsible or liable for indirect or consequential
damages resulting from the use or application of the product.
Reproduction of the contents of this manual, in whole or in part, without written permission from
ProSoft Technology is prohibited.
Information in this manual is subject to change without notice and does not represent a
commitment on the part of ProSoft Technology Improvements and/or changes in this manual or the
product may be made at any time. These changes will be made periodically to correct technical
inaccuracies or typographical errors.
Warnings
UL Warnings
Warning - Explosion Hazard - Substitution of components may impair
A
suitability for Class I, Division 2.
Warning - Explosion Hazard - When in Hazardous Locations, turn off
B
power before replacing or rewiring modules.
Warning - Explosion Hazard - Do not disconnect equipment unless power
has been switched off or the area is known to be nonhazardous.
Suitable for use in Class I, division 2 Groups A, B, C and D Hazardous
C
Locations or Non-Hazardous Locations.
ATEX Warnings and Conditions of Safe Usage:
Power, Input, and Output (I/O) wiring must be in accordance with the authority
having jurisdiction
Warning - Explosion Hazard - When in hazardous locations, turn off power
A
before replacing or wiring modules.
Warning - Explosion Hazard - Do not disconnect equipment unless power
B
has been switched off or the area is known to be non-hazardous.
These products are intended to be mounted in an IP54 enclosure. The
C
devices shall provide external means to prevent the rated voltage being
exceeded by transient disturbances of more than 40%. This device must
be used only with ATEX certified backplanes.
DO NOT OPEN WHEN ENERGIZED.
D