Table 4 Ap100 Boot Status Information (Led 2); Table 5 Ap100-Controller Runtime Status Information (Led 2) - Meru Networks AP100 Installation Manual

Table of Contents

Advertisement

Checking LED Activity
Table 4: AP100 Boot Status Information (LED 2)
AP100 LED activity
Red, one second
Black, five seconds
Yellow/Green, alternating for five seconds
Red, for one quarter second
Varies
After the boot is complete, LED 2 cycles to show the access point-controller runtime status. These
LED states are shown in Table 5.
Table 5: AP100-Controller Runtime Status Information (LED 2)
State
Initializing
Connected
Authenticated
Initialization
failed
Disconnected
Standalone
Downloading
Error State
16
Installing the Meru Air Point 100
Interpretation
In the process of initializing. The AP is con-
nected but not authenticated.
Normal operation without security
Normal operation with security
Configuration was downloaded, but AP ini-
tialization failed. AP automatically reboots.
Access point was once connected to a con-
troller and configured by the controller, but
can no longer find that controller
Access point is operating in a standalone
mode
Downloading image or configuration from
the controller
Access point is in an error state. Call Meru
technical support
Boot Stage
Power on
Access point self-test
Downloading image from the controller
Download complete
Operating status indicated by Table 5
AP100 LED Cycle
Green/Yellow/Red/
Green/Red/
Green/Yellow/Red/
Green/Red
Green/Off/Green/Off
Green blink, blink,
blink; Green long blink,
Green long blink
Red/Off/Red/Off
Green/Yellow/
Green/Yellow
Green/Long Yellow/
Long Green/Yellow/
Green/Long Yellow/
Long Green/Yellow
Off/Yellow/Off/Yellow/
Off/Green/Off/Green/
Off/Yellow/Off/Yellow/
Off/Green/Off/Green
Long Red/Off/Yellow/
Long Off/
Long Red/Off/ Yellow/
Long Off

Advertisement