S P E C I F I C AT I O N S
Media:
Material:
Fluid temp:
Electronics temp:
Power requirements:
Accuracy:
Repeatability:
Resolution:
Minimum water detection:
Outputs:
Mounting:
Pressure ratings:
Flow conditions:
Sensor dimensions:
EX enclosures:
Shaft length:
Pipe Size:
Weight:
* The KAM
OWD
must be installed in accordance with API MPMS Chapter 8, Section 2, Table 1.
®
®
**If entrained gas is constant, its effect is factored out. If entrained gas is introduced or removed after OWD
calibration it will shift water cut measurement by approximately 1-2% for every 1% change in gas levels.
OWDMANUAL 1114
Crude oil, refined products and chemicals
Wetted parts - 316 stainless steel / titanium (Other materials available)
T
o 300ºF (149ºC) High temp model available to 600ºF (315ºC)
-40
F to 158
F (-40
c to +70
º
º
º
24 VDC/1 amp at 24 watts
1% of full range**
+/- 0.01%
+/- 0.01%
100 PPM
4–20 mA
4-20 mA or 0–5 VDC
Alarm relay
RS232/RS485
HART
½", ¾", 1" or 2" FNPT flow through
(Other sizes, including metric, are available)
2" MNPT seal housing
2", 3", or 4" flanged seal housing
ANSI 150, 300, 600, 900, 1500
Well mixed in accordance with API MPMS Chapter 8, Section 2, Table 1
Ø1.5" x 4.5" to 14.5" (38mmh x 114mm to 368mm) depending on range
Sensor electronics - 3" x 6" x 3"
(76mm x 152mm x 76mm)
12" to 36"
(305mm to 914.4mm)
Off-the-shelf lengths are 12", 24", and 36"
(609.6mm, 762mm, 914.4mm,)
½" to 48" (15mm to 1200mm)
from 20 lbs. (9kg)
C) Temps below 0
º
º require heat tracing
4
®