gefran AGy -L Instruction Manual page 34

Lift vector ac drives
Table of Contents

Advertisement

Code Display (Description)
S.180 Car max speed
Speed of the lift car (m/s) when the inverter outputs the rated frequency.
S.200 Frequency ref 0
See description of S.207.
S.201 Frequency ref 1
See description of S.207.
S.202 Frequency ref 2
S.203 Frequency ref 3
S.204 Frequency ref 4
S.205 Frequency ref 5
S.206 Frequency ref 6
S.207 Frequency ref 7
Frequency references (Hz) of the inverter. The selection of any of the above references is performed by the dedicated
selectors (Freq Sel 0 to 4). Although only 8 references are present in the startup menu, it is possible to use up to 16 different
references, available in the menu F.
S.220 Smooth start frq
Frequency reference (Hz) used during the smooth start procedure.
S.225 Ramp factor 1
Ramp accel/decel and jerks are defined by the parameters described below. However, for an easy setting, it is possible to
use a common extension factor to speed-up or slow down the ramps. For example, if S.225 is set to 0.5, all the parameters
related to the sets 1 and 3 of ramps (accels, decels and jerks) are halved, resulting in slower ramps.
S.226 Ramp factor 2
Same as S.225, but it applies to the ramp sets 2 and 4.
S.230 Jerk acc ini 1
Jerk (m/s
) applied at the beginning of an acceleration with ramp set 1 (Ramp set 1 is the one used by default, during normal
3
operation).
S.231 Acceleration 1
Linear acceleration (m/s
S.232 Jerk acc end 1
Jerk (m/s
) applied at the end of an acceleration with ramp set 1.
3
S.233 Jerk dec ini 1
Jerk (m/s
) applied at the beginning of a deceleration with ramp set 1.
3
S.234 Deceleration 1
Linear deceleration (m/s
S.235 Jerk dec end 1
Jerk (m/s
) applied at the beginning of a deceleration with ramp set 1.
3
S.240 Jerk acc ini 2
Jerk (m/s
) applied at the beginning of an acceleration with ramp set 2 (Ramp set 2 is the one used by default when a short
3
floor is detected).
(linked to A.090)
(linked to F.100)
(linked to F.101)
(linked to F.102)
(linked to F.103)
(linked to F.104)
(linked to F.105)
(linked to F.106)
(linked to F.107)
(linked to F.116)
(linked to A.091)
(linked to A.092)
(linked to F.251)
(linked to F.201)
) with ramp set 1.
2
(linked to F.252)
(linked to F.253)
(linked to F.202)
) with ramp set 1.
2
(linked to F.254)
(linked to F.255)
Def.
Min.
Max
0.50
0.01
5.00
10.0
-F.020 F.020
50.0
-F.020 F.020
0.0
-F.020 F.020
2.0
-F.020 F.020
1.00
0.01
2.50
1.00
0.01
2.50
0.50
0.01 10.00
0.60
0.01
5.00
1.40
0.01 10.00
1.40
0.01 10.00
0.60
0.01
5.00
1.00
0.01 10.00
0.50
0.01 10.00