Term. Designation
1
Digital Output 4-NO
2
Digital Output 4-COM
3
Digital Output 4-NC
4
Digital Input 8
5
Digital Input 7
6
Digital Input 6
7
Digital Input 5
8
COM-IN Digital Inputs
9
+ 24V OUT
10
0 V 24 - GND Dig. Inputs
11
0 V 24 - GND Dig. Inputs
16
Digital Output 1
17
Digital Output 2
Term. Designation
18
Digital Output 3 - NO
19
Digital Output 3 - COM
20
Digital Output 3 - NC
21
GROUND REF
22
Digital Input 1
23
Digital Input 2
24
Digital Input 3
25
Digital Input 4
26
Analog Output 1
27
Analog Input 2
28
Analog Input 3
29
+10V OUT
30
Analog Input 1
31
0 V 10 - GND
32
-10V OUT
33
Analog Output 2
34
COM Digital outputs
n.a. = not assigned
+24Vdc voltage, which is used to externally supply the regulation card has to be stabilized and with a
maximum ±10% tolerance. The maximum absorption is 1A.
It is not suitable to power supply the regulation card only through a unique rectifier and capacitive filter.
ENC-EXP-AGy card
The EXP-ENC-AGy card allows the connection of a digital encoder TTL (+5V) or HTL (+24V)
Default setting = HTL (+24V).
See chapter 8 - Encoder Interface - for further information.
Function
Programmable digital relay output, default: [2] Drive OK (max 1A 30Vdc/250Vac)
Programmable digital input - Default: Fault Reset src
Programmable digital input - Default: Ext fault src
Programmable digital input - Default: Freq Sel 3 src
Programmable digital input - Default: Freq Sel 2 src
Supply reference for Digital inputs (max 6mA @ +24V)
+ 24 V potential voltage reference (max 300mA)
0 V 24 reference for Digital inputs
0 V 24 reference for Digital inputs
Programmable digital output - Default: [51] Contactor
Programmable digital output - Default: [32] Freq<thr1
Function
Programmable digital relay output
Default: [54]Brake cont, (max 1A 30Vdc/250Vac)
Ground shield cable reference
Programmable digital input - Default: Enable src
Programmable digital input- Default: Run Fwd src
Programmable digital input - Default: Run Rev src
Programmable digital input - Default: Freq sel 1 src
Programmable analog output - Default: [0] Output freq, (±10V / max 5mA)
Programmable VOLTAGE analog input - Default: n.a. , (±10V / max 0,5mA)
Programmable CURRENT analog input - Default: n.a. , ( max 20mA)
+ 10 V potential voltage reference, (max 10mA)
Programmable VOLTAGE analog input - Default: n.a. ,(±10V / max 0,5mA)
0 V 10 reference for analog inputs/outputs
- 10 V potential voltage reference, (max 10mA)
Programmable analog output - Default: [2] Output curr,(±10V / max 5mA)
Common reference for Digital outputs (open-collector)