Installation And Configuration; Step 1 - Get Ready - Extron electronics HC 402 Setup Manual

Hide thumbs Also See for HC 402:
Table of Contents

Advertisement

HC 402 • Setup Guide (Continued)

Installation and Configuration

ATTENTION:
• Installation and service must be performed by experienced personnel.
• L'installation et l'entretien doivent être effectués par du personnel expérimenté.
Step 1 — Get Ready
Familiarize yourself with the features of the transmitter and receiver (see
1.
Features
on page 3).
Download and install the latest version of the following:
2.
PCS Product Configuration Software — for detecting and configuring the AV settings for the transmitter-receiver pair
Toolbelt software — for discovering the HCR 102 receiver and other control products on the network, for managing
core settings, and for upgrading firmware if the need arises
Global Configurator
modes include a link to the Toolbelt software.
IP Link
 Pro device drivers — for use with GC, to make control of other AV devices possible
®
All are avail able from
Obtain network information for the unit from the network administrator. You will need the following details for each HCR 102
3.
receiver and for any other Extron Pro control product that is part of the system:
DHCP setting (on or off)
Device (HCR 102) LAN IP address
Write down the MAC address of each HCR 102 (see
4.
Obtain model names and setup information for devices the HCR 102 will control.
5.
Step 2 — Mount the Receiver, Prepare the Installation Site for
the HCT 101 D
Turn off or disconnect all equipment power sources and mount the
transmitter and receiver as required.
Mounting the HCR 102
The HCR 102 receiver ships with furniture mounting brackets
attached for mounting to furniture or a wall.
NOTE:
The receiver is designed so that its vents face
away from the wall or furniture when mounted in order to
achieve optimal air circulation and cooling.
Each receiver is one inch high, one half rack wide, and can
be rack mounted. The product page on
includes links to recommended optional rack shelves or rack
mounting kits. Alternatively, you can remove the pre-installed
furniture mounting brackets and attach four rubber feet at the
corners of each unit and place it on a table or desk.
Observe local and UL safety guidelines for mounting devices
to equipment racks. See the HC 400 Series User Guide for UL
rack mounting guidelines.
Prepare the Installation Site for the HCT 101 D
ATTENTION:
• Installation and service must be performed by authorized personnel only.
• L'installation et l'entretien doivent être effectués uniquement par un technicien qualifié.
• Extron recommends installing the HCT 101 D into a grounded, UL Listed electrical junction box.
• Extron recommande d'installer le HCT 101 D dans un boîtier d'encastrement électrique mis à la terre, certifié UL.
4
(GC) software — for setting up and configuring the control system. GC Professional and GC Plus
®
www.extron.com
Locating Software, Firmware, and Driver Files on the Extron Website
(see
www.extron.com
Front Panel Features
Subnet mask
Gateway IP address
O
figure
4,
on the previous page) or other IP Link Pro device to be used.
Figure 5.
and
Rear and Side Panel
on page 16).
Username
Passwords
Mounting the Receiver

Advertisement

Table of Contents
loading

Table of Contents