Chapter 2 - Installation
Name
Description
SIGNAL
Link Quality Indication
SCAN button
Initiating Scanning Mode
RF (behind cap)
SMA Jack
* After power-up, the SIGNAL LEDs illuminates for a few seconds until self-test is
finished.
38
Table 2-7: Si CPE Top Panel Components
Functionality
LEDS 1 - 7 Off, STATUS is green: 3 dB ≤ SNR < 5 dB
LED 1 On: 5 dB ≤ SNR < 8 dB
LEDs 1 - 2 On: 8 dB ≤ SNR < 12 dB
LEDs 1 - 3 On: 12 dB ≤ SNR < 15 dB
LEDs 1 - 4 On: 15 dB ≤ SNR < 18 dB
LEDs 1 - 5 On: 18 dB ≤ SNR < 20 dB
LEDs 1 - 6 On: 20 dB ≤ SNR < 25 dB
LEDs 1 - 7 On: SNR ≥ 25 dB
LEDs 1 - 7 Blinking simultaneously ((300ms on, 300ms off):
RSSI ≥ -20 dBm (saturation)
LEDs 1 - 7 Blinking one after the other (LED-1: 200ms on then
off, LED-2: 200ms on then off, up to LED-7 and then LED-1
again): During full frequency scan.
LEDs 1 - 7 Blinking as follows: LED 4 lights, after 200ms LEDs
3 & 5 light, after 200ms LEDs 2&6 light, after 200ms LEDs 1&7
light, after 200ms all the LEDs are extinguished and then the
sequence is repeated. During Best AU selection process.
Press for less than 3 seconds to initiate Best AU selection
process without full scanning. It means that the CPE scans
only the AUs detected in the last full scan. For each AU, all
relevant antennas are scanned. The LEDs will be blinking as
mentioned above for Best AU operation.
Press for 3 seconds or more to initiate full scan, prepare an
updated best AU list and select the best AU. The LEDs will be
blinking as mentioned above for full scan operation.