Chapter 2 - Installation
lightly squeeze the cap. Carefully insert the cable with the assembled
connector through the groove.

Figure 2-7: Inserting the IDU COM Cable into the Sealing Cap

Connect the Ethernet cable to the IDU COM RJ-45 connector.
2
Put the sealing cap back in its place. Make sure that the small protrusion on
3
the side of the cap fits inside the hole on the connector's protective body.

Figure 2-8: Connecting the IDU COM connector and inserting the Sealing Cap

Use appropriate sealing material to protect the connection against moisture
4
and humidity. Use removable sealing material, such as a tar seal, to enable
future access to the connector.
Route the cable to the location selected for the indoor equipment.
5
Assemble an RJ-45 connector with a protective cover on the indoor end of the
6
IDU-ODU cable. Refer to the pin assignment and color codes in standard
cables described above.
30
BreezeMAX CPEs Product Manual