Chapter 4 - Operation
NOTE
When the SU is synchronized with a base station, it receives the TFTP Server IP Address from the
base station during the network entry process. This address is 1.7.1.1 for a Base Station (NPU)
and 1.1.1.1 for a Micro Base Station. This will be the TFTP Server IP Address after each reset, as
long as the SU is associated with a base station.
The same TFTP Server IP Address parameter is used in the SW Download, Configuration File
Download and Configuration File Upload processes.
4.4.5.3.3
Configuration File Upload Name
Select this option to enter the name in the TFTP server directory of the
configuration file to be uploaded. A Configuration File Upload Name consists of up
to 50 characters.
The default Configuration File Upload Name is SU_UPLOAD_CFG.
4.4.5.3.4
Perform Configuration Upload
Select this option to execute the configuration file upload operation. To avoid
unintentional actions you will be prompted to confirm the request.
To perform configuration file upload:
Typically it is recommended to configure the IP address of the PC to
1
192.168.254.250, which is the default TFTP Server IP address of the unit. If a
different IP address is configured in the PC with the TFTP server, configure the
TFTP Server IP address to the same address.
Enter the name of the configuration file (as will appear in the TFTP server) as
2
the Configuration File Upload Name.
Select Perform Configuration Upload and confirm the dupload request. Wait to
3
receive a success/failure message.
4.4.6

Ethernet Port Operation Mode

The Ethernet Port Control parameter enables viewing and defining the operation
mode of the Ethernet port
The available options are:
Show Ethernet Mode
Set Ethernet Mode
86