Alvarion BreezeMAX PRO-S CPE Product Manual page 147

Table of Contents

Advertisement

Problem and Indication
The Ethernet Activity and/or
Integrity LEDs are on, but
no management access
using Telnet or web
browser, and the unit does
not respond to ping.
After power-up, STATUS
LED does not illuminate, at
least one of the SIGNAL
LEDs illuminate
BreezeMAX CPEs Product Manual
Possible Cause
Wrong IP configuration
Wrong Ethernet port
operation mode
ARP table in the PC
contains a wrong MAC
address for the
192.168.254.251 IP
address (due to a recent
connection to another SU).
Bridging table in SU is full
(expected when Number of
Supported Devices,
configurable from the Base
station's side, is set to a
small number.
STATUS LED failure
Unit failure
Corrective Action
Make sure that the PC is on the same subnet as the
unit. The unit's IP address for management
purposes is 192.168.254.251, and the subnet mask
is 255.255.255.0.
Make sure that the speed and duplex settings in the
PC match the configuration in the unit. The default
operation mode is Auto Negotiation, and supported
speeds are 10/100 Mbps, Full or Half Duplex.
Perform arpV-d at the DOS command prompt to
clear the ARP table, and retry the Telnet command
to the unit.
Reset the SU to clear the table and retry the Telnet
command to the unit.
Try completing the installation process.
If the installation process fails, contact the supplier.
Si CPE Troubleshooting
125

Advertisement

Table of Contents
loading

This manual is also suitable for:

Breezemax si cpe

Table of Contents